E3ZM-R66 датащи(PDF) 11 Page - Omron Electronics LLC

номер детали E3ZM-R66
подробное описание детали  Mark Sensor with Stainless Steel Housing Compact, Photoelectric Sensor with Built-in Amplifier and Teaching Function
PDF  16 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  OMRON [Omron Electronics LLC]
домашняя страница  http://www.omron.com/index3.html
Logo OMRON - Omron Electronics LLC

E3ZM-R66 датащи(HTML) 11 Page - Omron Electronics LLC

Back Button E3ZM-R66 Datasheet HTML 7Page - Omron Electronics LLC E3ZM-R66 Datasheet HTML 8Page - Omron Electronics LLC E3ZM-R66 Datasheet HTML 9Page - Omron Electronics LLC E3ZM-R66 Datasheet HTML 10Page - Omron Electronics LLC E3ZM-R66 Datasheet HTML 11Page - Omron Electronics LLC E3ZM-R66 Datasheet HTML 12Page - Omron Electronics LLC E3ZM-R66 Datasheet HTML 13Page - Omron Electronics LLC E3ZM-R66 Datasheet HTML 14Page - Omron Electronics LLC E3ZM-R66 Datasheet HTML 15Page - Omron Electronics LLC Next Button
Zoom Inzoom in Zoom Outzoom out
 11 / 16 page
background image
E3ZM-V
11
Operating Procedure
Two-point Teaching Using Teaching Button
1. Place the point for which you want the output to go ON in the beam spot position.
Then, press and hold the teaching button for at least 2 seconds.
The teaching indicator (red) will begin flashing quickly. (This indicates that the output ON teaching
operation should begin.)
Perform the following operation within 7 seconds of when you start pushing the button. (After 7 seconds,
the Unit will return to its initial condition.)
2. Press the teaching button for approximately 0.5 second.
The teaching indicator (red) will light for approximately 0.5 second to show that the output ON
teaching is completed.
The teaching indicator (red) will then begin flashing quickly again to show that the output OFF teaching
operation should begin.
3. Place the point where you want the output to go OFF in the beam spot position.
4. Press the teaching button for approximately 0.5 second.
The teaching indicator (red) will light for approximately 0.5 second to show that the output OFF
teaching is completed.
When Teaching Is Successful
When Teaching Is Not Successful
The stability indicator (green) shows that detection is stable.
The teaching indicator (red) flashes
slowly.
(Flashes in cycles of approx.
6 seconds.)
1.Lights
→ This indicates stable detection,
even if there is some fluttering
in the sensing object.
2.Flashes
→ This indicates the possibility of
unstable detection, due to
fluttering in the sensing object.
3.Remains OFF
→ This indicates unstable
detection.
Repeat the operation starting with step 1.
The Sensor enters normal operating condition.
Sensor
Background
Mark
Flashes quickly
Lit for approximately
0.5 second
Flashes quickly
Sensor
Background
Mark
Lit for approximately
0.5 second
Flashes slowly
Flashes
Off
Lit
Stable detection
Unstable detection
ON point
OFF point
Lit
Lit
Off
Lit
Lit
Off
Off
Off



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com