  FP-1103 Datasheet HTML 1Page - TOKYO KEISO CO.,LTD. FP-1103 Datasheet HTML 2Page - TOKYO KEISO CO.,LTD. FP-1103 Datasheet HTML 3Page - TOKYO KEISO CO.,LTD. FP-1103 Datasheet HTML 4Page - TOKYO KEISO CO.,LTD. FP-1103 Datasheet HTML 5Page - TOKYO KEISO CO.,LTD. FP-1103 Datasheet HTML 6Page - TOKYO KEISO CO.,LTD. FP-1103 Datasheet HTML 7Page - TOKYO KEISO CO.,LTD. FP-1103 Datasheet HTML 8Page - TOKYO KEISO CO.,LTD. FP-1103 Datasheet HTML 9Page - TOKYO KEISO CO.,LTD. Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 12 page
background image
FT-1000/FP-1000 FLOAT TYPE TANK GAUGES
TG-L2512-E00
2
TOKYO KEISO CO., LTD.
OPERATION PRINCIPLE
As shown in Fig. 1
The FT-1000 Series Level Gauge consists of a level detecting float,
transmitting parts (tape, guide elbow, etc.) and the instrument body.
The indicator body comprises the sprocket pulley, tape winding pul-
ley, constant torque spring, gear machanism, pointer and scale plate.
When a transmitter is provided for the level gauge, the transmitter is
connected to the sprocket pulley shaft of the indicator body through
the coupling mechanism.
The float is kept afloat on the surface of the liquid with a constant
draft line, and follows any changes in the liquid level. The float is con-
nected to a tape winding pulleythrough the stainless steel tape which
is punched at regular intervals. The constant torque spring is incorpo-
As shown in Fig. 2
In the FP-1000 Series Level Gauge, the vapor and gas in the tank
are sealed with the seal pipe and cannot get into the level gauge.
Therefore, the system is not only covenient but suitable to measure
the liquid level of tanks that contain a liquid, liquified gas or any other
high temperature liquid and that can generate poisonous, corrosive
or inflammable gases and odor. In addition, the system is excellent so
that it is non-corrosive, safe and is easy to maintain.
In the FP Series, the indicator body of the FT-1000 level gauge for
low pressue is used, and a seal pipe made of a non-magnetic ma-
Installing on the side a tank
Construction of the seal pipe and float
Fig. 2: OPERATION PRINCIPLE OF FP-1000
Local level
indicator
Seal pipe
Float (contains
main maget)
Measuring tape
Following magnet
Main magnet
Float
Bottom of tank
Bottom piece
Seal pipe
(Float guide pipe)
Float
Tank
Liquid surface
Guide elbow
Guide elbow
Measuring tape
Sprocket pulley
Gear mechanism
Pointer-scale plate
(or counter)
Constant torque spring
(Conston spring)
Coupling
Indicator body of
FT-1000 Series
Level Gauge
Tape winding pulley
Level, analog, digital
Level signal line,
Alarm singnal line
Cam
Microswitch
Upper, lower limit alarm transmitter
Analog converter/transmitter
Digital converter/transmitter
Alarm transmitter
Fig. 1: OPERATION PRINCIPLE OF FT-1000
rated in the tape winding pulley in order to apply a constant torque
in the tape winding direction. This constant torque is balanced with
the weight of the float on the surface of the liquid.
When the float rises and lowers, according to the change in the
liquid level, the tape which is interlocked with the float rotates the
sprocket pulley, which in turn is engaged with the punched tape.
The rotation corresponds to the upward or downward movement of
the float. Thus, any change in the level of the liquid is converted to
the change in the rotation angle of the sprocket pulley shaft.
This rotation angle of sprocket pulley is transferred to transmitter
unit, i. e. Microswitch alarm, pneumatic, electric, digital BCD etc.
through coupling unit for remote data transmission.
terial is inserted and fixed in the tank. The doughnut-shaped float
rises and lowers, with the aid of the seal pipe as guide, according to
the change in the liqud level. The float contains a main magnet, and
a following magnet with a sliding roller is arranged in the seal pipe.
The following magnet is connected to the local level indicator as well
as FT-1000 level gauge, by means of a measuring tape in order to
transmit the change in the liquid level; (to the level indicator, which
indicates the liquid level.) If a transmitter is equipped, the liquid level
can be transmitted to a remote control room.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com