13 / 29 page ![]() 13 TURN ON QCL INSTRUMENT 1. Press the Power switch on the back panel to |. The front panel power button light slowly pulses. 2. Press the Power button on the front panel, the button illuminates, touchscreen is activated, and the Control screen is active. NOTE: Turning off front Power button powers down the application electronics and puts the unit into standby mode. Turning off rear Power switch powers down all electronics and settings return to factory default. 3. The front panel displays dashes instead of digits until the unit has finished its power-up sequence (~10 seconds). SET LIMITS 1. Press to access the Limit Screen. 2. Press Limit Current, Maximum Supply Voltage, and/or Cable Resistance values and rotate the Adjustment knob to change each value. The instrument will beep when set. Figure 15. Limit Screen NOTES: • The Limit Current should not exceed the damage current threshold of your QCL. • The Maximum Internal Supply Voltage can be lowered to minimize internal instrument temperature or to act as a compliance voltage clamp on the QCL output current. See Additional Technical Notes on page 25 for optimization instructions. • The Cable Resistance range is 0 – 4 Ω. QCL Voltage displays the voltage at the QCL DSUB or SMA terminals. To account for voltage loss across the cable to the QCL, you can enter a non-zero value for Cable Resistance. The QCL Voltage will now display as: Voltage Displayed = Voltage@Pins - (Cable Resistance x Operating Current) • The minimum limit current is about 8% of full scale. ADJUST THE SETPOINT 1. Press to access the Control Screen. 2. Press the Setpoint value and turn the Adjustment knob until the desired operating current is displayed. Figure 16. Control Screen NOTE: The Control screen is on by default when the instrument is turned on. The Mode is Constant Current by default and cannot be changed. DISPLAY EXISTING CURRENT AND VOLTAGE VALUES Press to access the Monitor Screen. Values on this screen cannot be changed and are for information only. Figure 17. Monitor Screen |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |