поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

LD310 датащи(PDF) 2 Page - Veris. All Rights Reserved.

номер детали LD310
подробное описание детали  Leak Detection
PDF  2 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  VERIS [Veris. All Rights Reserved.]
домашняя страница  https://www.veris.com/
Logo VERIS - Veris. All Rights Reserved.

LD310 датащи(HTML) 2 Page - Veris. All Rights Reserved.

  LD310 Datasheet HTML 1Page - Veris. All Rights Reserved. LD310 Datasheet HTML 2Page - Veris. All Rights Reserved.  
Zoom Inzoom in Zoom Outzoom out
 2 / 2 page
background image
or
SC
NSC
End Terminator
(EOL)
Leader cable kit
(LC-Kit)
Spot detector
(SD-Z)
LD1000
LD310
2.5”
(63.5 mm)
4.4”
(112 mm)
LD310
Power
Fault
Leak
Quiet/Reset/Test
5.5”
(140 mm)
4.2”
(105 mm)
Alarm/Zone 1
Alarm/Zone 2
Alarm/Zone 3
Power
Alarm/Zone 4
Alarm/Zone 5
Alarm/Zone 6
Test/Reset/Silence
8.0”
(203 mm)
10.5”
(267 mm)
MODEL
MANUF. PART #
DESCRIPTION
U006-0080*
LD310*
Leak Panel, 1 zone, LED, 2 relay outputs
U006-0001** LD1000**
Leak Panel/Remote Annunciator, 1 zone,
supervised, relay output
U006-0036** LDRA6**
Leak Panel, up to 6 zones, supervised,
relay output, Modbus RTU
U006-0035
LC-KIT***
Leader cable kit for SC cables (connects
from leak panel to SC or NSC cable)
U006-0037
WA-DC-05
Power Supply for LD300
U006-0084
PS-WA-DC-24
Power Supply for LD1000 and LDRA6
MODEL
LED INDICATION
DEVICE STATUS
LD310
Solid green (on or off)
Normal operation
LD310
Flashing green (0.5 sec on/2.5 sec off)
Cable fault
LD310
Flashing green (0.5 sec on/0.5 sec off)
Leak detected
LD1000
Solid green (on or off)
Normal operation
LD1000
1 amber
Cable fault
LD1000
1 red
Leak detected
LDRA6
Solid green (on or off)
Normal operation
LDRA6
1 green
Power on
LDRA6
1 red
Leak detected
LDRA6
1 yellow
Cable fault
LD310
Wiring Diagram
LD310
Dimensional Drawing
LD1000
Dimensional Drawing
LD310 OR LD1000 BASIC INSTALLATION WITH
SC SENSING CABLE AND SD-Z SPOT DETECTOR
Wiring Diagram
LDRA6
Dimensional Drawing
ORDERING INFORMATION
BLINK CODE KEY
* Power supply not included; requires U006-0037 power supply.
** Power supply not included; requires U006-0084 power supply.
*** Included with LD310 and LD1000.
Be sure the leader
cable is wired into
the correct pinouts.
5VDC
Power
Input
Cable Fault
Relay Output
Leak
Relay Output
Top 2 Pins - Supervised
Bottom 2 Pins - Non-supervised
LED
Audible
Alarm
Silence/Test/
Reset Button
Circuit
Board
Clip
L Brackets
Plastic
Peg
JP3 - Audible Alarm
Top 2 Pins - Disabled
Bottom 2 Pins - Enabled
JP1 - Leak Sensitivity
Top 2 Pins - Most sensitive
No Jumper - Medium sensitivity
Bottom 2 Pins - Least sensitive
Plastic
Peg
Leader Cable /
Leak Detection
Input
ACCESSORIES P. 153
800.354.8556 | +1 503.598.4564 | sales@veris.com | intl@veris.com | veris.com
Leak Detection | LD310, LD1000, & LDRA6
Leak Detection | Zone Leak Detection Panels
HQ0001795.H 0321



Html Pages

1 2


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com