поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

9790 датащи(PDF) 2 Page - Time Electronics Ltd.

номер детали 9790
подробное описание детали  5077 Series 2 Multifunction Power Calibrator
PDF  2 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  TIME-ELECTRONICS [Time Electronics Ltd.]
домашняя страница  https://www.timeelectronics.com/
Logo TIME-ELECTRONICS - Time Electronics Ltd.

9790 датащи(HTML) 2 Page - Time Electronics Ltd.

  9790 Datasheet HTML 1Page - Time Electronics Ltd. 9790 Datasheet HTML 2Page - Time Electronics Ltd.  
Zoom Inzoom in Zoom Outzoom out
 2 / 2 page
background image
Time Electronics
5077 Series 2 Multifunction Power Calibrator
Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom
T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com
Technical Specifications (for full technical data see extended specifications sheet)
Function
Range / Values
Best 1 year Specification
DC Voltage
0 to ± 1050 V
± 40 ppm of setting
DC Current
0 to ± 22 A
1000 A with clamp meter adaptor (option 9780)
± 120 ppm of setting
DC Power
(simultaneous output of V & I)
23 kW / 23 kVA
DCV: 2 mV to 1050 V
DCI: 2 mA to 22 A
*
± 100 ppm of setting
± 150 ppm of setting
AC Voltage
2 mV to 1050 V / 20 Hz to 20 kHz sine-wave
± 0.05 % of setting
AC Current
10 μA to 22 A / 20 Hz to 5 kHz sine-wave
100 A with current transformer (option 9790)
1000 A with clamp meter adaptor (option 9780)
± 0.07 % of setting
AC Power
(simultaneous output of V & I)
23 kW / 23 kVA, 40 to 500 Hz
ACV: 2 mV to 1050 V
ACI: 2 mA to 22 A
*
± 0.05 %
± 0.1 %
Phase
± 90.0°, 40 to 500 Hz
± 0.25°
Power Factor
0.00 to 1.00, 40 to 500 Hz
Option 9780: Clamp meter adaptor
AC/DC Current up to 1000 A (DC, 45 to 90 Hz)
± 0.5 %
* The accuracy of the power is complex and is determined by using a formula, which combines the errors due to Voltage, Current, and Phase.
Power Accuracy (%) = SqrRt (Voltage Accuracy2 + Current Accuracy2 + Phase Correction2). Where Phase Correction (%) = 100x(1-Cos(Phase+PhaseAcc)/Cos Phase)
External Options
External Adaptors/Instruments
9780: Clamp meter adaptor (1 and 50 turn coil) • 9790: 100 Amp AC current transformer
Accessories
9085: Soft carry case • 9059: Hard transit case • 9728: 19 " Universal rack mount kit • 9796: Premium test lead set
EasyCal Software
ECFLA: EasyCal full license • 9777: Bar code reader • 9779: Job and address label printer
EC2FL/EC2WL: Additional user licenses • EAD: EasyAdmin add-on • CREP: Crystal Reports software
General Specifications
Mains voltage.......................................100 to 260 V AC 50/60 Hz.
Fuse ratings .........................................3.15 A anti-surge.
Power consumption ............................120 W typical, 200 W maximum.
Temperature performance..................Operating: 10 to 40 °C. Storage: –10 to 50 °C.
Operating humidity..............................< 80 % non condensing.
Altitude .................................................0 to 3 km. Non operating: 3 to 12 km.
Warm up ...............................................30 minutes to full accuracy.
Interfaces..............................................RS-232, GPIB and USB (via RS-232 adaptor). Command set: Standard SCPI.
Dimensions / Weight ...........................W 447 x H 152 x D 470 mm. Weight: 16.5 kg.
Supplied accessories..........................Test lead set, calibrator control software (1 year license), RS-232 cable, RS-232 to USB adaptor, user manual.
Ordering Information
5077-S2 .............................................. 5077 Series 2 Multifunction Power Calibrator
................................................................. AC/DC 1050 V / 22 A, 23 kW single-phase power calibration.
....................................................................Supplied with test lead set, calibrator control software (1 year license), traceable calibration certificate.
5077-S2/ACRD................................... 5077 Series 2 Multifunction Power Calibrator with accredited calibration
................................................................. AC/DC 1050 V / 22 A, 23 kW single-phase power calibration.
...................................................................Supplied with test lead set, calibrator control software (1 year license), ISO 17025 calibration certificate.
9780 ......................................................Single/50-turn current clamp adaptor
9790 ......................................................100 Amp AC current transformer
S2PTL ...................................................Series 2 premium test lead set
ECFLA...................................................EasyCal Software (see separate datasheet for options).
Due to continuous development Time Electronics reserves the right to change specifications without prior notice.
v1b
01/24



Html Pages

1 2


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com