| поискавой системы для электроныых деталей |
|
X20105 датащи(PDF) 2 Page - United Automation Ltd. All rights reserved |
|
|
|||||||||||||||||||||||||||||
X20105 датащи(HTML) 2 Page - United Automation Ltd. All rights reserved |
|
2 / 4 page ![]() X20105 Components and Spares | Automation Control System 9 Channel HMI D/A Signal Controller System Installation & User Manual BMF House - Wight Moss Way, Southport Business Park Southport PR8 4HQ ENGLAND, UNITED KINGDOM Contact Us: 0044 (0) 1704-516 501 enquiries@united-automation.com www.united-automation.com unitedautomationltd UA_Limited 14 July 2025 | Issue: 5 Page 2 of 4 INSTALLATION CIRCUIT A typical system with 3 x D/A units is shown below: CONFIGURATION OPTIONS The HMI unit can control up to 3 D/A units, the HMI selects a particular D/A unit by means of a 2 bit address. The address of each D/A unit is selected by switches 3 and 4, on DIP switch SW1, on each D/A unit. Switch 4 on SW1 is used to set the least significant bit of the address, switch 3 on SW1 is used to set the most significant address. The HMI unit uses addresses 01, 10 and 11 to access the three D/A units. The 9 possible output channels, as indicated on the HMI display, are mapped across the 3 D/A units. The Table below shows how to set up the D/A switches for the three allowable address values and how the displayed channels are mapped to each D/A unit: D/A 1 D/A 2 D/A 3 Switch setup xx01 Switch setup xx10 Switch setup xx11 Mapped Channels 1,2,3 Mapped Channels 4,5,6 Mapped Channels 7,8,9 Switches 1 and 2 on SW1 are not used and are ignored by the D/A and HMI units. Please note that the D/A units should be set up with unique addresses; duplication of D/A addresses will result in unknown output levels being driven on the analogue outputs. SET UP CAUTION! Ensure the mains supply is disconnected before proceeding. Set the D/A address switches on each D/A unit to a unique address, refer to the "Configuration Options" section. Connect the HMI unit to the D/A slave units using four core, dual twisted pair type cable, the cable should have a minimum gauge of 26AWG. One twisted pair should be used for the RS485 A and B signals, the other for the power connection. The corresponding signals on each unit should be connected, namely: A, B, +, -. L N + - B A + - AC INPUT 24VDC RS485 24VDC 110VAC-230VAC INPUT AC OR DC POWER ANALOGUE OUTPUTS - 0-5VDC Channel 1 Channel 2 Channel 3 +Vs -Vs +Vs -Vs +Vs -Vs |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |