| поискавой системы для электроныых деталей |
|
ACS150 датащи(PDF) 6 Page - ABB |
|
|
|||||||||||||||||||||||||||||
ACS150 датащи(HTML) 6 Page - ABB |
|
6 / 12 page ![]() 6 ABB micro drives ACS150 | Catalog Control connections and interfaces Application macros Application macros are preprogrammed parameter sets. When starting up the drive, the user typically selects one of the macros that is best suited for the application. The diagram below gives an overview of ACS150 control connections and shows the default I/O connections for the ABB standard macro. ABB micro drives have six standard macros: – ABB standard macro – 3-wire macro – Alternate macro – Motor potentiometer macro – Hand/auto macro – PID control macro In addition to the standard macros the user can create three user macros. The user macro allows the user to save the parameter settings for later use. EMC filter grounding screw (EMC) Removable clip for brand labeling Integrated interface FlashDrop connection Integrated potentiometer I/O connections Varistor grounding screw (VAR) Analog input signal selector (U/I) Input, brake resistor and motor connections ROCOM RONC RONO +24 V 0 V const. speed 1 I U I U ROCOM RONC RONO R < 10 k Ω SCR AI GND +10 V +24 V GND DCOM DI1 DI2 DI3 DI4 DI5 ramp pair sel. const. speed 1 fwd/ rev start/ stop DI configuration NPN connected (sink) ACS150 ACS150 SCR AI GND +10 V +24 V GND DCOM DI1 DI2 DI3 DI4 DI5 start/ stop fwd/ rev DI configuration PNP connected (source) with external power supply 0 - 20 mA Ground the cable screen on the sourcing end Screen Potentiometer Analog input 0 to 10 V Reference voltage +10 V DC, max. 10 mA Aux. voltage output +24 V DC, max. 200 mA PROGRAMMABLE DIGITAL INPUTS DI5 can also be used as a frequency input FlashDrop 6 PE L1 L2 L3 3-phase power supply, 200 to 480 V AC Input choke EMC filter Output choke PE U1 V1 W1 U2 V2 W2 EMC VAR SCR AI GND +10 V +24 V GND COM DI1 DI2 DI3 DI4 DI5 COM NC NO AC motor M 3 ~ Brake chopper BRK+ BRK- Brake resistor t° SI AI I U EMC filter grounding screw Relay output 250 V AC / 30 V DC / 6 A Varistor grounding screw Typical I/O connections |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |