EVAL-AD421EB датащи(PDF) 4 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
EVAL-AD421EB датащи(HTML) 4 Page - Analog Devices |
|
4 / 7 page ![]() EVAL-AD421EB REV. A –4– The evaluation software does not allow another application running under Windows to access the printer port while it is running. Control of the printer port is returned when the AD421 application program is quit. MAIN MENU WINDOW Once the OK button of the port selection window has been pressed the user is presented with the Main Menu Window for the application. The window is called AD421 Evaluation Board Utility and is as shown in Figure 3. This utility contains the following sections: interface, setup output and programmed output. INTERFACE SECTION The interface section contains buttons that control the method in which data is loaded to the AD421 and also the printer port selection. The following is a description of these buttons. Load Input Reg When this button is clicked the input register of the AD421 is loaded with the data as programmed in the Setup Output section. Data is only loaded to the input register and is not transferred to the DAC register. No output update takes place in this case. DAC Latch When this button is clicked the data in the input register of the AD421 is transferred to the DAC register and an output update takes place. This basically activates the LATCH input to the AD421. Load + Latch When this button is clicked the input register of the AD421 is loaded with the data as programmed in the Setup Output Section and the LATCH signal is also activated updating the output of the AD421. This is a combination of the previous two buttons. Port Selection This button returns the user to the previous menu on Parallel Port Selection. The selected port appears in the box at the bottom on the interface section. SETUP OUTPUT SECTION This section allows the user to select one of three current output setup modes and also allows the selection of either 4-20mA normal mode of operation or the selection of an alarm current mode where the current range is from 3.5-24mA. The following is a description of these buttons. Setup Mode There are three selections in this setup, the programmed output current can be programmed as a straight mA by selecting the mA button. The second button, % Fullscale, allows the output current to be programmed as a percentage of the fullscale output. The third selection allows the user to enter the HEX data value to be loaded to the input register as the method of programming the output current. Alarm Current On This button is used to select between the normal 4-20mA output and the alarm current output. When this button is not selected the normal 4-20mA output range is selected. When the alarm current on is selected an "x" appears in the box and the output range can be programmed from 3.5mA to 24mA. PROGRAMMED OUTPUT This section shows the programmed output current as a current in mA, as a % of Fullscale and as the HEX value that has been written to the input register. The Binary Output Box shows in the form of a LED display the data that has been loaded to the AD421. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |