| поискавой системы для электроныых деталей |
|
M34116 датащи(PDF) 9 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M34116 датащи(HTML) 9 Page - STMicroelectronics |
|
9 / 23 page ![]() INSTRUCTION SET OPERATING MODES Two different operating mode istructions are available: M116 Operating Mode: Sending this operating mode instruction, the device functionality is the same as M116 and M116 instruc- tion set is selected (refer to the following M116 instruction set for further details). Control Signal Data Bus CS RD C/D WR D7 D6 D5 D4 D3 D2 D1 D0 01 10 X E F1 F0 0 101 y E = 1 extra bit y F1– F0 = 00 no bit inverted 01 even bit inverted 10 odd bit inverted 11 all bit inverted Default values after reset: E = 0 F1– F0 = 11 if MU Law F1– F0 = 01 if A Law M34116 Operating Mode: Sending this operating mode instruction, the M34116 instruction set and functionality are selected Control Signal Data Bus CS RD C/D WR D7 D6 D5 D4 D3 D2 D1 D0 01 10 X E F1 F0 1 001 yE = 1 extra bit yF1– F0 = 00 no bit inverted 01 even bit inverted 10 odd bit inverted 11 all bit inverted Note: Upon reset M116 instruction set is automatically selected. To switch from the M116 instruction set the above M34116 operating mode instruction is necessary. The operating mode instruction, when necessary, must be sent just after reset. M34116 INSTRUCTION SET. INSTRUCTION 1: M34116 CHANNEL CONNECTION IN CONFERENCE MODE Five bytes are needed: Control Signal Data Bus CS RD C/D WR D7 D6 D5 D4 D3 D2 D1 D0 0 1 0 0 X X S P4P3 P2P1P0 0 1 0 0 X X X Al4 Al3 Al2 Al1 Al0 0 1 0 0 X X X AO4 AO3 AO2 AO1 AO0 0 1 0 0 X PTC5C4C3 C2C1C0 01 10 X X X X 0 111 y S: Start bit y Al4–Al0: Al4 = 1 Al4 = 0 Al3–Al0 Input attenuationor gain ( ±15dB) gain attenuation value in dB (0–15) y Ol4–AO0: AO4 = 1 AO4 = 0 AO3–AO0 output attenuation or gain ( ±15dB) gain attenuation value in dB (0–15) y PT: Phase toggle conference y P4–P0: Conference number (1–29) y C5–C0: Channel number (0–63) When S = 1 the conference register is cleared. S = 1 can be used only when connecting the first channel to a new conference. When PT = 1 the sign of the PCM samples is changed before they are put in conference. This corresponds to a phase shift of 180 ° and may be used to reduce the electrical echo. Note: Unspecified Data Bus can be either 0’s or 1’s M34116 9/23 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |