1908 датащи(PDF) 4 Page - Thurlby Thandar Instruments Ltd. |
|
|
|||||||||||||||||||||||||||||
1908 датащи(HTML) 4 Page - Thurlby Thandar Instruments Ltd. |
|
4 / 4 page ![]() Technical Specifications - 1908 and 1908P Brochure Part No. 82100-1530 Issue 3 MEASUREMENT PARAMETERS & ACCURACY Accuracies apply for 1 year 19°C to 25°C. Temperature coefficient outside these limits is <0.1 x quoted range accuracy per °C. Scale Length The scale length is 120,000 counts (unless otherwise stated) giving a maximum measured value for each range of 119999. Thus for the 100V range the maximum measured value is 119.999 volts Accuracies are quoted in terms of a percentage of the measured value plus a number of least significant digits. Reading Rate Varies with measurement parameter. Selectable as 4 readings/second or 20 readings/second for most parameters. DC Voltage Range Accuracy Resolution Input Impedance 100mV 0.02% ± 3 digits* 1µV 10.11M Ω 1000mV 0.02% ± 3 digits 10µV 10.11M Ω 10V 0.02% ± 3 digits 100µV 10.0M Ω 100V 0.02% ± 3 digits 1mV 10.1M Ω 1000V 0.02% ± 3 digits 10mV 10.11M Ω * after null Typical Input 10MW//<1000pF, except for Vdc plus Vac measurement when the Impedance: 1MW AC attenuator is in parallel with the 10MW DC attenuator. Maximum Input: 1kV DC or AC peak, any range. NMR: >60dB at 50/60Hz. CMR: 1kW unbalanced CMR is >90dB at DC/50Hz/60Hz. Recommended max.peak AC + DC voltage while measuring DC voltage Range 100mV 1000mV 10V 100V 1000V Max. AC 1.8V 1.8V 18V 180V 1000V The table shows the maximum peak AC (45Hz-50Hz) plus DC voltage that can be applied without affecting the accuracy of the DC measurement due to overload clamping. These values only apply when the DC component does not exceed the range maximum and the analogue 50/60Hz rejection filter is enabled. AC Voltage (True RMS) Range Accuracy Resolution 45Hz - 10kHz 10kHz - 30kHz 30kHz - 50kHz 100mV 0.2% ± 150 dig. 1.5% ± 200 dig. - 1µV 1000mV 0.2% ± 100 dig. 0.5% ± 100 dig. 2% ± 200 dig. 10µV 10V 0.2% ± 100 dig. 0.5% ± 100 dig. 2% ± 200 dig. 100µV 100V 0.2% ± 100 dig. 0.5% ± 100 dig. 2% ± 200 dig. 1mV 750V 0.2% ± 100 dig. 0.5% ± 100 dig. 2% ± 200 dig. 10mV Accuracy specifications apply for readings between 10,000 and 120,000 counts. Maximum crest factor = 3 at nominal range maximum. Input Impedance: 1MW//<1000pF Maximum Input: 750V rms, 1000V peak; any range. CMR: 1kW Unbalanced CMR is >60dB at DC/50Hz/60Hz AC + DC Voltage Total measurement error will not exceed the sum of the separate AC and DC accuracy specifications plus 10 digits. Resistance 2-wire or 4-wire measurement Range Accuracy Resolution 100W 0.05% ± 8 digits 1mW 1000W 0.05% ± 5 digits 10mW 10kW 0.05% ± 5 digits 100mW 100kW 0.05% ± 5 digits 1W 1000kW 0.3% ± 2 digits 10W 10MW 0.3% ± 2 digits 100W Maximum Input: 1000V DC or AC rms, any range. Max. O/C Voltage: 3.5V DC Current Range Accuracy Resolution 10mA 0.05% ± 5 digits 100nA 100mA 0.05% ± 5 digits 1µA 1000mA 0.2% ± 5 digits 10µA 10A (<5A) 0.2% ± 5 digits 100µA 10A (>5A) 0.5% ± 10 digits 100µA Maximum Input: mA ranges - 1.6A DC or AC rms, 1000V, fuse protected. 10A range - 10A DC or AC rms, 1000V, fuse protected. Voltage Burden: 10mA range - <100mV; 100mA, 1A, 10A ranges - <600mV AC Current (True RMS) Range Accuracy (45Hz to 10kHz) Resolution 10mA 0.35% ± 20 digits 100nA 100mA 0.35% ± 20 digits 1µA 1000mA 0.5% ± 20 digits 10µA 10A (<5A) 0.5% ± 20 digits 100µA 10A (>5A) 1% ± 20 digits 100µA Accuracy specifications apply for readings between 10,000 and 120,000 counts. Maximum crest factor = 3 is typically 0.5%. Maximum Input: mA ranges - 1.6A DC or AC rms, 1000V, fuse protected. 10A range - 10A DC or AC rms, 1000V, fuse protected. Voltage Burden: 10mA range - <100mV; 100mA, 1A, 10A ranges - <600mV AC + DC Current Total measurement error will not exceed the sum of the separate AC and DC accuracy specifications plus 10 digits. Frequency Range Accuracy Resolution 100Hz 0.01% ± 1 digit 0.01Hz 1000Hz 0.01% ± 1 digit 0.1Hz 10kHz 0.01% ± 1 digit 1Hz 100kHz 0.01% ± 1 digit 10Hz Scale Length: 12,000 counts Frequency Range: 10Hz to >100kHz Input sensitivity: Better than 30mVrms (100mV range); better than 10% of range for all other Vac and Iac ranges. Capacitance Range Accuracy Resolution 10nF 2% ± 5 digits 10pF 100nF 2% ± 5 digits 100pF 1µF 2% ± 5 digits 1nF 10µF 2% ± 5 digits 10nF 100µF 5% ± 5 digits 100nF Scale Length: 1200 counts Temperature Linearised measurement for PT100 or PT1000 RTD probes, 2-wire or 4-wire measurement, display in oC or oF. RTD Range Accuracy Resolution PT100 -50 to 400oC 0.05% ± 0.5oC 0.1oC PT1000 -50 to 400oC 0.05% ± 0.5oC 0.1oC N. B. Accuracy specifications apply to multimeter only, they do not account for additional probe accuracy errors. Continuity and Diode Test Continuity: 100W range selected; audible tone sounds for impedance <10W. Diode Test: Test current approximately 1mA; displays voltages up to 1.2V. Max. O/C Voltage: 3.5V Maximum Input: 1000V DC or AC rms, any range. Designed and built in Europe by: Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon, Cambridgeshire. PE29 7DR United Kingdom Tel: +44 1480 412451 Fax: +44 1480 450409 Email: info@aimtti.com Web: www.aimtti.com Technical Specifications - 1908 and 1908P (continued) Available from: EXTERNAL REMOTE TRIGGER (TTL/CMOS) Connection: Terminal block on rear panel. Input: Input to the LED of an opto-isolator through 1kW resistor. Apply >+3V to trigger remote input. Max. Voltage 10V. Output: Opto-isolated open collector output, conducts for 250ms on completion of input trigger. Max. off-state Voltage: 10V. On state sink current 2mA (typical). DISPLAY Display Type: High contrast backlit transflective LCD. Main display 5½ digits 17mm high, Secondary display 6 digits 10mm high. Scale Length: 120,000 counts for most measurement parameters Annunciators: LCD annunciators for all ranges, functions and program modes. Overrange: Displays OFL if input too large for range. Overflow: Displays -Or- if calculated result overflows display. COMPUTING FUNCTIONS Null (Relative) Stores current reading and subtracts it from future readings. W Null: Additional non-volatile function for nulling test lead resistance. Hold: Reading is frozen T-Hold: (Touch & Hold) Reading is frozen when stable. dB: Displays measurement in dBm relative to 600W or other user-entered impedance. AC plus DC: The RMS value of the AC plus DC parts of the signal is calculated and displayed. % Deviation: Displays % deviation from entered reference value. Ax+b: Linear scaling of results, with offset. Limits: Reading displayed with HI, LO, or PASS with respect to user-defined high and low limits. Min/Max: Minimum and maximum reading stored. Power: Calculates V2/R and displays in Watts with respect to a user-defined impedance. VA: Calculates and displays Volts x Amps. Data Logger: Manual or automatic storage of 500 measurements. Storage interval 1s to 9999s or at the measurement sample rate, manually from keyboard, or by external triggering. DIGITAL INTERFACES - 1908 Full digital remote control facilities are available through a USB connection. USB: Standard USB 2.0 hardware connection. Host Powered. DIGITAL INTERFACES - 1908P Full digital remote control facilities are available through the RS232, LAN, USB and GPIB interfaces.(AC line power is required for RS232, LAN and GPIB interfaces.) RS232: Standard 9-pin D-connector. Baud rate 9600. USB: Standard USB 2.0 hardware connection. Host powered. LAN: Ethernet 100/10base-T hardware connection. LXI Conformance: 1.4 LXI Core 2011. GPIB (optional): Conforms with IEEE488.1 and IEEE488.2. Remote Command Processing Time: Typically <100ms. SOFTWARE SUPPLIED IVI Driver: An IVI driver for Windows is supplied. LV/CVI Driver: Full installation for CVI and LabVIEW instrument drivers. USB Driver: An installation file is supplied calling a standard Windows* USB driver. POWER REQUIREMENTS AC Input: 220V-240V or 110-120V AC ±10%, 50/60Hz, by internal adjustment; 20VA max. Installation Category II. Batteries: Internal rechargeable Nickel Metal Hydride Battery Life: > 20 hours with the backlight enabled. Battery life can be increased to > 35 hours with the backlight disabled. GENERAL Operating Range: +5°C to + 40°C, 20% to 80% RH Storage Range: -20°C to + 60°C Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2. Safety and EMC: Complies with EN61010-1, EN61010-2-030, EN61010-2-033 & EN61326-1. For details, request the EU Declaration of Conformity for this instrument via http://www.aimtti.com/support (serial no. needed) Security: Kensington security slot incorporated. Size: 250(W) x 97(H) x 295(D)mm in bench-top configuration 213.5(W) x 86.5(H) x 269(D)mm (2U/ ½ - rack) in rack mount format. Weight: 3.2kg. Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications without prior notice. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |