| поискавой системы для электроныых деталей |
|
L6238 датащи(PDF) 23 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6238 датащи(HTML) 23 Page - STMicroelectronics |
|
23 / 35 page ![]() the pole necessary for loop stability. Thus the loop bandwidth is actually limited by the motor it- self. Figure 19 shows the complete transconductance loop including compensation, plus the response. The Bode plot depicts the normal way to achieve stability in the loop. The pole and zero are used to set a gain of 20dB at a higher frequency and the pole of the motor cuts the gain to achieve stabil- ity. Loop instability may be caused by two factors: 1)The motor pole is too close to the zero. Refer- ring to figure 20, the zero is not able to decre- ment the shift of phase, and when the effect of the pole is present, the phase shift may reach 180 ° and the loop will oscillate. To rec- tify this situation, the pole/zero must be shifted at lower frequencies by increasing the compensation capacitor. 2)The motor capacitance, CM, itself can inter- fere with the loop, creating double poles. If the gain at higher frequencies is low, this dou- ble pole will not be able to reach a critical value due to it’s 40dB/decade slope. Figure 21 illustrates performance with low gain. Al- though the gain decrease at a rate of 40dB/decade, the phase does not reach 180 ° of shift. If the gain at higher frequencies is sufficiently high, the double pole slope of 40dB/decade can cause the phase shift to reach 180 °, resulting in oscillation. Figure 22 is a Bode plot showing how to correct this situation. The bold line indicates the response with relatively high gain at the higher frequencies. By leaving the pole un- changed and increasing the zero, the response indicated by the dashed lines can be achieved. 5.6 Slew Rate Control A 3-phase motor appears as an inductive load to the power supply. The power supply sees a dis- turbance when one motor phase turns OFE and another turns ON because the FET turn-OFF time is much shorter than the L/R rise time. Abrupt FET turn-OFF without a proper snubbing circuit can even cause current recirculation back into the supply. However, the need for a snubber circuit can be eliminated by controlling the turn-OFF time of the FETs. Figure 20: Motor Pole. Figure 21: Effect of Cm. Figure 22: Correct Compensation. L6238 23/35 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |