| поискавой системы для электроныых деталей |
|
MP8796B датащи(PDF) 24 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP8796B датащи(HTML) 24 Page - Monolithic Power Systems |
|
24 / 52 page ![]() MP8796B – 16V, 30A, SYNCHRONOUS STEP-DOWN CONVERTER WITH PMBUS MP8796B Rev 1.0 www.MonolithicPower.com 24 1/19/2020 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2020 MPS. All Rights Reserved. The MP8796B provides output voltage monitoring through register READ_VOUT (8Bh). To achieve correct output voltage setting and monitoring, the registers VOUT_COMMAND (21h), VOUT_MARGIN_ HIGH (25h), VOUT_MARGIN_LOW (26h), and VOUT_SCALE_LOOP (29h) should be set correspondingly. Follow the steps below to set the output voltage to 2.5V: 1. Determine the Vo_set source using the OPERATION (01h) command. Assume that VOUT_COMMAND (21h) is selected. 2. Choose the D1[1:0] value based on the Vo_set value. The D1[1:0] value should pull the FB voltage as close to 600mV as possible. In this case, both D1[1:0] = 2’b10 and D1[1:0] = 2’b11 can provide VO = 2.5V. However, D1[1:0] = 2’b10 yields a 625mV FB voltage, while D1[1:0] = 2’b11 yields a 312.5mV FB voltage. Choose D1[1:0] = 2’b10. 3. Set VOUT_SCALE_LOOP (29h) to 0x00FA to match D1[1:0] = 2’b10. 4. Set VOUT_COMMAND (21h) to 0x4E2 (LSB = 2mV). 5. VOUT_COMMAND (21h) must be sent after VOUT_SCALE_LOOP (29h) and D1h. Otherwise, the change of VOUT_SCALE_ LOOP (29h) and D1h will not be effective. 6. VOUT_COMMAND (21h) cannot exceed the minimum/maximum value specified in Table 2. Power Good (PG) The MP8796B has a power good (PG) output. PG is the open drain of a MOSFET. Connect PG to VDRV or another external voltage source below 3.6V through a pull-up resistor (typically 100kΩ). After applying the input voltage, the MOSFET turns on, and PG is pulled to GND before soft start is ready. After the FB voltage (VFB) reaches the threshold set by PMBus command POWER_GOOD_ON, PG is pulled high after a delay set by PMBus. The delay can be chosen through the PMBus command MFR_CTRL_VOUT (D1h) [5:2]. When the converter encounters any fault (e.g. UV, OV, OT, UVLO), PG is latched low and cannot be pulled high again until a new soft start initiates. When the MP8796B is configured as the master in single- or multi-phase operation, the PG pin is used for fault indication. Therefore, PG must be pulled high to ensure proper operation. Otherwise, the MP8796B may enter a protection mode. This slave fault detection feature can be enabled or disabled through the PMBus bit D0h[0]. If the input supply fails to power the MP8796B, PG is clamped low even though it is tied to an external DC source through a pull-up resistor. Figure 8 shows the relationship between the PG voltage and the pull-up current. 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 0.6 0.65 0.7 0.75 0.8 0.85 0.9 VPG (V) Figure 8: PGOOD Clamped Voltage vs. Pull-Up Current |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |