17 / 38 page ![]() Bandgap Voltage Reference CFILT = 1 µF CL = 47 µF RESR = 5 PŸ RFILT Buffer + VIN OUT_S OUT_F FILT VIN GND_S GND_F Power Supply SS REF60xx RLIM = 120 NŸ EN GND REF + VIN R = 1 NŸ RF = 5 Ÿ CF = 10 nF THS4521 AINP AINN ADS8881 Copyright © 2016, Texas Instruments Incorporated R = 1 NŸ R = 1 NŸ R = 1 NŸ RF = 5 Ÿ Power Supply 17 REF6025, REF6030, REF6033, REF6041, REF6045, REF6050 www.ti.com SBOS708B – MAY 2016 – REVISED AUGUST 2016 Product Folder Links: REF6025 REF6030 REF6033 REF6041 REF6045 REF6050 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Reference Droop Measurements (continued) Figure 46 shows the setup that was used to measure the reference droop. The output ADC code was captured using a field-programmable gate array (FPGA), and post-processing was done on a personal computer. The input to the THS4521, and hence in turn to the ADS8881, is a constant dc voltage (close to positive or negative full-scale because this condition is the worst-case for charge drawn from the REF pin). The dc source must have extremely low noise. After the REF60xx device is powered up and stable, the FPGA sends commands to the ADS8881 to capture data in bursts. The ADS8881 is initially in idle mode for 100 ms. The FPGA then sends a command to the ADS8881 to perform 100 conversions at 1 MSPS. The ADC code corresponding to these 100 conversions (one burst of data) is stored as the first row in a 1000 × 100 dimensional array. This operation is repeated 1000 times, and the data corresponding to each burst is stored in a new row of the 1000 × 100 dimensional array. Finally, each column in this array is averaged to get a final data-set of 100 elements. This final data-set now has code spread that is much less than 1 LSB because most of the noise has now been removed through averaging. This data-set was plotted on a graph with X axis = column number (each column number corresponds to 1 µs of time because the sampling rate is 1 MSPS), and Y axis = ADC output code to obtain reference-droop measurements. Figure 46. Burst-Mode Measurement Setup |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |