| поискавой системы для электроныых деталей |
|
ISO7420FEDRG4 датащи(PDF) 18 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
ISO7420FEDRG4 датащи(HTML) 18 Page - Texas Instruments |
|
18 / 35 page ![]() ISO7420E, ISO7420FE, ISO7421E, ISO7421FE SLLSE45F – DECEMBER 2010 – REVISED JULY 2015 www.ti.com 8.3.2 Insulation Characteristics over recommended operating conditions (unless otherwise noted) PARAMETER(1) TEST CONDITIONS SPECIFICATION UNIT DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 VIORM Maximum workingisolation voltage 566 VPEAK Method a, After environmental tests subgroup 1, VPR = VIORM x 1.6, t = 10 s, 906 Partial Discharge < 5 pC Method b1, VPR Input-to-output test voltage VPR = VIORM x 1.875, t = 1 s (100% Production test) 1062 VPEAK Partial discharge < 5 pC After Input/Output safety test subgroup 2/3, VPR = VIORM x 1.2, t = 10 s, 680 Partial discharge < 5 pC VTEST = VIOTM = 4242 VPK VIOTM Maximum transient isolation voltage t = 60 sec (qualification) 4242 VPEAK t= 1 sec (100% production) RS Isolation resistance VIO = 500 V at TS = 150°C >109 Ω Pollution degree 2 UL 1577 VTEST = VISO = 2500 VRMS, t = 60 sec (qualification); VISO Maximum withstand isolation voltage 2500 VRMS VTEST = 1.2 x VISO = 3000 VRMS, t = 1 sec (100% production) (1) Climatic Classification 40/125/21 Table 1. IEC 60664-1 Ratings Table PARAMETER TEST CONDITIONS SPECIFICATION Basic isolation group Material group II Rated mains voltage ≤ 150 VRMS I–IV Installation classification Rated mains voltage ≤ 300 VRMS I–III 8.3.3 Regulatory Information VDE CSA UL CQC Certified according to DIN V VDE V 0884-10 (VDE V 0884- Approved under CSA Component Recognized under UL 1577 Certified according to GB 10):2006-12 and DIN EN Acceptance Notice 5A, IEC 60950-1, Component Recognition Program 4943.1-2011 61010-1 (VDE 0411-1):2011- and IEC 61010-1 07 2500 VRMS Isolation Rating; Basic insulation per CSA 60950-1- Basic Insulation; 07+A1 and IEC 60950-1 2nd Ed+A1, Basic Insulation, Altitude ≤ Maximum Transient Isolation 384 VRMS maximum working voltage; Single Protection Isolation Voltage, 5000 m, Tropical Climate, 250 Voltage, 4242 VPK; CSA 61010-1-04 and IEC 61010-1 2500 VRMS (1) VRMS maximum working Maximum Working Isolation 2nd Ed, 300 VRMS maximum working voltage Voltage, 566 VPK voltage for basic insulation and 150 VRMS for reinforced insulation Certificate number: Certificate number: 40016131 Master contract number: 220991 File number: E181974 CQC14001109540 (1) Production tested ≥ 3000 VRMS for 1 second in accordance with UL 1577. 18 Submit Documentation Feedback Copyright © 2010–2015, Texas Instruments Incorporated Product Folder Links: ISO7420E ISO7420FE ISO7421E ISO7421FE |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |