9 / 40 page ![]() Table 5-2. Insulation Characteristics PARAMETER TEST CONDITIONS SPECIFICATION UNIT DW DWW DTI Distance through the insulation Minimum internal gap (internal clearance) 21 21 μm VIOWM Maximum working isolation voltage Time dependent dielectric breakdown (TDDB) test 1500 2000 VRMS 2121 2828 VDC DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 VIOTM Maximum transient isolation voltage VTEST = VIOTM t = 60 sec (qualification) t= 1 sec (100% production) 8000 8000 VPK VIOSM Maximum surge isolation voltage Test method per IEC 60065, 1.2/50 µs waveform, VTEST = 1.6 × VIOSM = 12800 VPK (1) (qualification) 8000 8000 VPK VIORM Maximum repetitive peak isolation voltage 2121 2828 VPK VPR Input-to-output test voltage Method a, After Input/Output safety test subgroup 2/3, VPR = VIORM × 1.2, t = 10 s, Partial discharge < 5 pC 2545 3394 VPK Method a, After environmental tests subgroup 1, VPR = VIORM × 1.6, t = 10 s, Partial Discharge < 5 pC 3394 4525 Method b1,After environmental tests subgroup 1, VPR = VIORM × 1.875, t = 1 s (100% Production test) Partial discharge < 5 pC 3977 5303 RS Isolation resistance VIO = 500 V at TS >109 >109 Ω Pollution degree 2 2 Climatic category 55/125/21 55/125/21 UL 1577 VISO Withstanding isolation voltage VTEST = VISO = 5700 VRMS, t = 60 sec (qualification); VTEST = 1.2 × VISO = 6840 VRMS, t = 1 sec (100% production) 5700 5700 VRMS (1) Testing is carried out in air or oil to determine the intrinsic surge immunity of the isolation barrier. Table 5-3. Package Insulation and Safety-Related Specifications (over recommended operating conditions (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT CLR External clearance Shortest terminal-to-terminal distance through air DW-16 8.15 mm DWW-16 14.5 15.0 CPG External creepage Shortest terminal-to-terminal distance across the package surface DW-16 8.15 mm DWW-16 14.5 15.0 CTI Comparative tracking index DIN EN 60112 (VDE 0303-11); IEC 60112; UL 746A 600 V RIO Isolation resistance, input to output(1) VIO = 500 V, TA = 25°C 1012 Ω VIO = 500 V, 100°C ≤ TA ≤ max 1011 Ω CIO Barrier capacitance, input to output(1) VIO = 0.4 x sin (2πft), f = 1 MHz 1 pF CI Input capacitance(2) VI = VCC/2 + 0.4 x sin (2πft), f = 1 MHz, VCC = 5 V 2 pF (1) All pins on each side of the barrier tied together creating a two-terminal device. (2) Measured from input pin to ground. www.ti.com ISO7821, ISO7821F SLLSEM2H – NOVEMBER 2014 – REVISED NOVEMBER 2024 Copyright © 2024 Texas Instruments Incorporated Submit Document Feedback 9 Product Folder Links: ISO7821 ISO7821F |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |