AMC7832IPAP датащи(PDF) 50 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AMC7832IPAP датащи(HTML) 50 Page - Texas Instruments |
|
50 / 74 page ![]() AMC7832 SLAS836 – MARCH 2014 www.ti.com Table 34. Register name: Alarm Status 1 – Address: 0x71, Default: 0x00 (READ ONLY) REGISTER DEFAULT ADDRESS BIT NAME DESCRIPTION NAME VALUE Alarm 0X71 7:4 Reserved Reserved for factory use 0000 Status 1 3 ALARMIN-ALR The ALARMIN-ALR is set to ‘1’ if the ALARMIN terminal is 0 enabled and set high. 2 THERM-ALR Thermal alarm flag. When the die temperature is equal to or 0 greater than +150°C, the bit is set ('1') and the THERM-ALR flag activates. The on-chip temperature sensor (LT) monitors the die temperature. If LT is disabled, the THERM-ALR bit is always '0'. The hysteresis of this alarm is 8°C. 1 LT-HIGH-ALR LT-LOW-ALR = '1' when the temperature sensor is out of the 0 range defined by the upper threshold. 0 LT-LOW-ALR LT-LOW-ALR = '1' when the temperature sensor is out of the 0 range defined by the lower threshold. Table 35. Register name: General Status – Address: 0x72, Default: 0x00 (READ ONLY) REGISTER DEFAULT ADDRESS BIT NAME DESCRIPTION NAME VALUE General 0x72 7:3 Reserved Reserved for factory use All zeros Status 2 Reserved Reserved for factory use 0 1 GALR Global alarm bit. 0 This bit is the OR function or all individual alarm bits of the status register. 0 DAVF ADC Data available flag bit. Direct mode only. Always cleared in 0 Auto mode. 0: ADC conversion is in progress or ADC is in Auto mode 1: ADC conversions are complete and new data is available 8.5.10 Temperature And GPIO Data: Address 0x78 – 0x7A Table 36. Register name: Temperature Data (low byte) – Address: 0x78, Default: 0x00 (READ ONLY) REGISTER DEFAULT ADDRESS BIT NAME DESCRIPTION NAME VALUE Temp Data 0x78 7:0 TEMP-DATA(7:0) Stores the temperature sensor reading in twos complement 0x00 (low) format. Table 37. Register name: Temperature Data (high byte) – Address: 0x79, Default: 0x00 (READ ONLY) REGISTER DEFAULT ADDRESS BIT NAME DESCRIPTION NAME VALUE Temp Data 0x79 7:4 Reserved Reserved for factory use. All zeros (high) 3:0 TEMP- Stores the temperature sensor reading in twos complement 0x00 DATA(11:8) format. Table 38. Register name: GPIO – Address: 0x7A, Default: 0xFF (READ/WRITE) REGISTER DEFAULT ADDRESS BIT NAME DESCRIPTION NAME VALUE GPIO 0x7A 7 GPIO-7 For write operation the GPIO terminal operates as an output. 1 Writing a ‘1’ to the GPIO-n bit sets the GPIO-N terminal to high 6 GPIO-6 1 impedance. Writing a ‘0’ sets the GPIO-n terminal to logic low. 5 GPIO-5 1 For read operations the GPIO terminal operates as an input. Read the GPIO-n bit to receive the status of the GPIO-n terminal. 4 GPIO-4 1 After power-on reset, or any forced hardware or software reset, 3 GPIO-3 1 the GPIO-n terminal has a 48-k Ω input impedance to IOVDD. 2 GPIO-2 1 1 GPIO-1 1 0 GPIO-0 1 50 Submit Documentation Feedback Copyright © 2014, Texas Instruments Incorporated Product Folder Links: AMC7832 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |