| поискавой системы для электроныых деталей |
|
AND9621 датащи(PDF) 2 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
AND9621 датащи(HTML) 2 Page - ON Semiconductor |
|
2 / 4 page ![]() AND9621/D www.onsemi.com 2 APPLICATIONS INFORMATION Q1: When running the AX::CodeBlocks IDE, I get the following pop−up message when I try to debug. What does it mean? Figure 1. A1: There are several reasons that this pop−up message can occur. The most likely cause for this pop−up is the ribbon cable between the AXDBG−2−GEVK board and the development board is not plugged in correctly. The debug link will not work and you will get the message shown above. The header for the ribbon cable is keyed on AXDBG−2−GEVK, and the ribbon cable should plug into the development board such that the ribbon cable faces away from the development board (as shown below). Figure 2. If the ribbon cable is plugged in correctly and the pop−up message is given, then the microcontroller is locked with a key. The locking is normally done as a security measure to avoid that the software can be read out or modified. If “Yes” is selected on the pop−up, all the factory calibration and any software stacks will be erased. Normally “No” is the appropriate response. NOTE: Devices that are sold pre−programmed with software stacks (with AT interface, such as AX−SFUS) are locked at the factory and the key is a secret. If reprogramming is attempted the calibration data and the software stack will be erased and this is non−recoverable and will render the chip inoperable. If problems remain, please review Q2 for tips on solving debug link and serial communication problems. Q2: I’m having serial communication problems or can’t get the AX debug link to connect to the development board. What can I do? A2: First check that the ribbon cable is plugged in correctly as shown in Q1 of this document. If the cable is plugged in correctly, then there may be a problem with the virtual COM port. Open the Windows device manager and verify a COM port is shown that corresponds to the AXDBG−2−GEVK board. See the picture below (USB Serial Port – COM8 in this example). If needed unplug and re−plug the AXDBG−2−GEVK board to verify that a COM port is associated with it. The first time an AXDBG−2−GEVK is plugged in, Windows may need time to find the driver. This normally takes less than 5 minutes. Once a valid driver is installed and the COM port shows up, there will be two serial converters, A and B, as shown in the picture below. Figure 3. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |