| поискавой системы для электроныых деталей |
|
LM73 датащи(PDF) 13 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LM73 датащи(HTML) 13 Page - Texas Instruments |
|
13 / 31 page ![]() TIME (Active Low) Measured Temperature THIGH Limit TLOW Limit ALERT 5HVHW %LW VHW WR ³1´ One Conversion Time ALERT TIME Measured Temperature THIGH Limit TLOW Limit ALERT pin 13 LM73-Q1 www.ti.com SNIS194 – DECEMBER 2016 Product Folder Links: LM73-Q1 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Figure 5. ALERT Temperature Response Cleared When Temperature Crosses TLOW Figure 6. ALERT Temperature Response Cleared by Writing a 1 to the ALERT Reset Bit. 7.3.6 Communicating With the LM73-Q1 The data registers in the LM73-Q1 are selected by the Pointer Register. At power-up the Pointer Register is set to 00h, the location for the Temperature Register. The Pointer Register latches the last location it was set to. Note that all Pointer Register bits are decoded; any incorrect pointer values will not be acknowledged and will not be stored in the Pointer Register. NOTE A write to an invalid pointer address is not allowed. If the master writes an invalid address to the Pointer Register, the LM73-Q1 will not acknowledge the address and the Pointer Register will continue to contain the last value stored in it. A Write to the LM73-Q1 will always include the address byte and the pointer byte. A Read from the LM73-Q1 can occur in either of the following ways: • If the location latched in the Pointer Register is correct (that is, the Pointer Register is pre-set prior to the read), then the read can simply consist of an address byte, followed by retrieving the data byte. Most of the time it is expected that the Pointer Register will point to Temperature Registers because that will be the data most frequently read from the LM73-Q1. • If the Pointer Register needs to be set, then an address byte, pointer byte, repeat start, and another address byte will accomplish a read. The data byte is read out of the LM73-Q1 by the most significant bit first. At the end of a read, the LM73-Q1 can accept either an Acknowledge or No Acknowledge bit from the Master. No Acknowledge is typically used as a signal to the slave that the Master has read its last byte. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |