| поискавой системы для электроныых деталей |
|
TSC2005 датащи(PDF) 39 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TSC2005 датащи(HTML) 39 Page - Texas Instruments |
|
39 / 46 page ![]() www.ti.com AUXILIARY AND TEMPERATURE MEASUREMENT t COORDINATE + OH3 f OSC )N @ (B)2) @ f OSC f ADC )OHCONV @ 1 f OSC ) L PPRO f OSC (12) CS Deactivated NoTouch Detected HostWriteto ControlByte1D[6:3] As DAV WaitingforHostto ReadAUXData CS Deactivated Reading AUX-Data Register Sample,Conversion,and AveragingforAUXMeasurement CS Deactivated P ogra r mm dfor Non-Continuous AUXMeasurement e t COORDINATE NoTouch Detected t COORDINATE + OH3 f OSC )N @ (B)2) @ f OSC f ADC )OHCONV @ 1 f OSC ) L PPRO f OSC (13) CS Deactivated NoTouch Detected HosttoWriteto ControlByte1D[6:3] As DAV CS Deactivated Reading AUX-Data Register Sample,Conversion, andAveragingfor AUXMeasurement CS Deactivated P ogra r mm dfor Continuous AUXMeasurement e CS Deactivated Reading AUX-Data Register t COORDINATE t COORDINATE t COORDINATE Sample,Conversion, andAveragingfor AUXMeasurement Sample,Conversion, andAveragingfor AUXMeasurement TSC2005 SBAS379C – DECEMBER 2006 – REVISED MARCH 2008 The TSC2005 can measure the voltage from the auxiliary input (AUX) and from the internal temperature sensor. Applications for the AUX can include external temperature sensing, ambient light monitoring for controlling backlighting, or sensing the current drawn from batteries. There are two converter functions that can be used for the measurement of the AUX: 1. Non-continuous AUX measurement shown in Figure 39 (converter function select bits C[3:0] = Control Byte 1 D[6:3] = 0101); or 2. Continuous AUX Measurement shown in Figure 40 (converter function select bits C[3:0] = Control Byte 1 D[6:3] = 1000). See Table 7 for more information on the converter function select bits. There are also two converter functions for the measurement of the internal temperature sensor: 1. TEMP1 measurement (converter function select bits C[3:0] = Control Byte 1 D[6:3] = 0110); or 2. TEMP2 measurement (converter function select bits C[3:0] = Control Byte 1 D[6:3] = 0111). See Table 7 for more information on the converter function select bits. For the detailed calculation of the internal temperature sensor, please see the SubSec1 9.3 section. These two converter functions have the same timing as the non-continuous AUX measurement operation as shown in Figure 39; therefore, Equation 12 can also be used for internal temperature sensor measurement. The time needed to make a non-continuous auxiliary measurement or an internal temperature sensor measurement is given by: Where: OH3 = overhead time #3 = 3.5 internal clock cycles. Figure 39. Non-Touch Screen, Non-Continuous AUX Measurement The time needed to make continuous auxiliary measurement is given by: Figure 40. Non-Touch Screen, Continuous AUX Measurement Copyright © 2006–2008, Texas Instruments Incorporated Submit Documentation Feedback 39 Product Folder Link(s): TSC2005 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |