  UCC2915DP.A Datasheet HTML 1Page - Texas Instruments UCC2915DP.A Datasheet HTML 2Page - Texas Instruments UCC2915DP.A Datasheet HTML 3Page - Texas Instruments UCC2915DP.A Datasheet HTML 4Page - Texas Instruments UCC2915DP.A Datasheet HTML 5Page - Texas Instruments UCC2915DP.A Datasheet HTML 6Page - Texas Instruments UCC2915DP.A Datasheet HTML 7Page - Texas Instruments UCC2915DP.A Datasheet HTML 8Page - Texas Instruments UCC2915DP.A Datasheet HTML 9Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 16 page
background image
UCC2915, UCC3915
15V PROGRAMMABLE HOT SWAP POWER MANAGER
SLUS198C – FEBUARY 2000 - REVISED - JUNE 2001
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
electrical characteristics, these specifications apply for TA = –40°C to 85°C for the UCC2915 and
0
°C to 70°C for the UCC3915, VIN = 12 V, IMAX = 0.4 V, SHTDWN = 2.4 V, TA = TJ, (unless otherwise
stated)
DAC (continued)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
Trip c rrent
Code = 1110
2.30
2.75
3.25
A
Trip current
Code = 1111
2.50
3.0
3.50
A
Max output current over trip
(current source mode)
Code = 0100 to 1111,
IMAX = 0 V
0.35
1.0
1.65
A
Max output current
(current source mode)
Code = 0100 to 1111,
IMAX = 2.4 V
3.0
4.0
5.2
A
NOTE 1: All voltages are with respect to GND. Current is positive into and negative out of the specified terminal.
fault timer
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
CT charge current
VCT = 1.0 V
–83
–62
–47
µA
CT discharge current
VCT = 1.0 V
0.8
1.2
1.8
µA
Output duty cycle
VOUT = 0 V
1.0%
1.9%
3.3%
CT fault threshold
1.2
1.5
1.7
V
CT reset threshold
0.4
0.5
0.6
V
NOTE 1: All voltages are with respect to GND. Current is positive into and negative out of the specified terminal.
shutdown
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
Shutdown threshold
1.1
1.5
1.9
V
Shutdown hysteresis
150
mV
Input current
100
500
nA
NOTE 1: All voltages are with respect to GND. Current is positive into and negative out of the specified terminal.
open drain output (FAULT)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
High level output current
FAULT = 5 V
250
µA
Low level output voltage
IOUT = 5 mA
0.2
0.8
V
NOTE 1: All voltages are with respect to GND. Current is positive into and negative out of the specified terminal.
TTL input dc characteristics
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
TTL input voltage high
2.0
V
TTL input voltage low
0.8
V
TTL input high current
VIH = 2.4 V
3
10
µA
TTL input low current
VIL = 0.4 V
1
µA
NOTE 1: All voltages are with respect to GND. Current is positive into and negative out of the specified terminal.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com