| поискавой системы для электроныых деталей |
|
ACS1/085S датащи(PDF) 4 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ACS1/085S датащи(HTML) 4 Page - STMicroelectronics |
|
4 / 8 page ![]() ACS108-5Sx 4/8 ® HIGH INDUCTIVE SWITCH-OFF OPERATION At the end of the last conduction half-cycle, the load current reaches the holding current level IH, and the ACS™ switch turns off. Because of the inductance L of the load, the current flows through the avalanche diode D and decreases linearly to zero. During this time, the voltage across the switch is limited to the clamping voltage VCL. The energy stored in the inductance of the load depends on the holding current IH and the inductance (up to 10 H); it can reach about 20 mJ and is dissipated in the clamping section that is especially designed for that purpose. AC LINE TRANSIENT VOLTAGE RUGGEDNESS The ACS108 switch is able to safely withstand the AC line transient voltages either by clamping the low energy spikes or by breaking over under high energy shocks. The test circuit in Figure 4 is representative of the final ACS™ application and is also used to stress the ACS™ switch according to the IEC61000-4-5 standard conditions. Thanks to the load, the ACS™ switch withstands the voltage spikes up to 2 kV above the peak line voltage. It will break over safely even on resis- tive load where the turn-on current rise is high as shown in Figure 4. Such non-repetitive testing can be done 10 times on each AC line voltage polarity. Fig. 1: Turn-off operation of the ACS108 switch with an electro valve: waveform of the gate current IG, pin OUT current IOUT & voltage VOUT. Fig. 2: ACS108 switch static characteristic. T ime (400µs/div) IOUT (10 mA/div) VOUT (200V/div) IH VCL = 650V IH VCL IOUT VOUT Fig. 3: Overvoltage ruggedness test circuit for resis- tive and inductive loads according to IEC61000-4-5 standard. R = 150 Ω, L = 5µH, VPP = 2kV. Fig. 4: Current and voltage of the ACS™ during IEC61000-4-5 standard test with a 150 Ω - 10µH load & VPP = 2kV. Iout (2 A/div) Vout (200 V/div) dI/dt = 100 A/µs RL RG= 220 Ω VAC +VPP AC LINE & SURGE VOLTAGE GENERATOR G COM OUT ACSxx ON S D |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |