29 / 43 page ![]() Multifunction Preset Counter H7CX (Counter Function) C-115 Note: 1. Counting cannot be performed during reset/reset 1 input. 2. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF. 3. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered. 4. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON. Input mode Operation after count completion UP/DOWN A, B, C Output mode setting K-2 The display continues to in- crease/decrease until the over- flow or underflow value is reached. One-shot output only. D The display continues to in- crease/decrease until the over- flow or underflow value is reached. The outputs are ON while the count is equal. L The display continues to in- crease/decrease until the over- flow or underflow value is reached. OUT1 is held while the present value is less than or equal to set value 1. OUT2 is held while the present value is greater than or equal to set value 2. H The display continues to in- crease/decrease until the over- flow or underflow value is reached. OUT1 is held while the present value is greater than or equal to set value 1. OUT2 is held while the present value is greater than or equal to set value 2. Note: H mode is available only when using a 6-digit model as a 2- stage counter. (The one-shot output time can be set in the range 0.01 to 99.99s.) Self-holding output Instantaneous (equals) output One-shot output 0 999999 −99999 OUT1 OUT2 Reset/ reset 1 Set value 2 Set value 1 0 999999 −99999 OUT1 OUT2 Reset/ reset 1 Set value 2 Set value 1 0 999999 −99999 OUT1 OUT2 Reset/ reset 1 Set value 2 Set value 1 0 999999 −99999 OUT1 OUT2 Reset/ reset 1 Set value 2 Set value 1 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |