| поискавой системы для электроныых деталей |
|
APL датащи(PDF) 13 Page - Sensata Technologies, Inc. |
|
|
|||||||||||||||||||||||||||||
APL датащи(HTML) 13 Page - Sensata Technologies, Inc. |
|
13 / 18 page ![]() APL/UPL - NOMINAL DCR / IMPEDANCE Current Ratings (Amps) Resistance (ohms) Impedance (ohms) Impedance (ohms) DC Delays AC, 50/60Hz Delays AC, 400Hz Delays 50 59 51, 52, 53 Dual Coil 51, 52, 53 60 69 600, 61, 62 71, 72, 73 64, 65, 66 Dual Coil 61, 62 40, 49 41, 42, 43 0.05 162 540 460 640 174 419 582 691 1975 1195 0.10 35.4 105 155 150 42.5 103.4 119.0 160 495 284 0.50 1.2 4.2 4.5 5.6 1.9 4 4.1 6.2 22 12 1.0 .236 1.02 1.2 1.41 .41 .955 1.08 1.56 5.01 2.72 5.0 .021 .048 .059 .070 .030 .045 .048 .068 .240 .140 10.0 .0060 .0121 .0140 .0160 .0075 .0105 .0134 .0174 .0520 .0283 15.0 .0040 .0067 .0092 .0100 .0038 .0068 .0070 .0120 .0260 .0140 20.0 .0032 .0047 .0052 .0070 .0024 .0049 .0050 .0069 .0140 .0088 30.0 .0021 .0036 .0036 .0040 .0022 .0032 .0035 .0037 .0079 .0043 50.0 .0020 .0024 .0026 .0023 .0020 .0020 .0025 .0030 .0036 .0028 Notes: DCR and impedance based on 100% rated current applied and stablized a minimum of one hour. Tolerance: .02 amperes to 2.5 amperes, ± 20%; 2.6 amperes to 20 amperes, ± 25%; 21 amperes to 50 amperes, ± 50%. Consult factory for special values and for coil impedance of delays not shown APL/UPL - RATINGS Configurations Current Ratings (Amps) Maximum Voltage Ratings Interrupting Capacity (Amps) Series Fuse Series and Shunt 0.050 - 50 65Vdc 5000 None 0.050 - 100 65Vdc 3000 None 0.050 - 60 120Vac (50/60Hz) 1000 None 0.050 - 50 120Vac (50/60Hz) 5000 4X (120 max.) 0.050 - 20 277Vac (50/60Hz) 5000 4X 0.050 - 50 250Vac (50/60Hz) 5000 4X (120 max.) 0.050 - 50 120Vac (400Hz) 1500 None 21 - 50 250Vac (400Hz) 1000 None 0.050 - 20 250Vac (400Hz) 2100 None Relay 0.050 - 50 50Vdc — — 0.050 - 50 120Vac (50/60Hz) — — 0.050 - 50 120Vac (400Hz) — — 0.050 - 50 250Vac (50/60Hz-400Hz) — — Switch Only 50 amperes max. 65Vdc — — — 100 amperes max. 32Vdc — — — 50 amperes max. 250Vac (50/60Hz) — — — 50 amperes max. 250Vac (400Hz) — — — Notes: DC units do not require series fusing. 277Vac: A circuit protector with this voltage rating is intended for 277Vac per pole single phase source only usage. (e.g.) If a two or three pole breaker is marked 277Vac, all line terminals must be connected to the same phase, assuming the 277Vac is taken from line to neutral of a three phase 277/480Vac system. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |