| поискавой системы для электроныых деталей |
|
AX1008DA датащи(PDF) 3 Page - AXElite technology co. ltd |
|
|
|||||||||||||||||||||||||||||
AX1008DA датащи(HTML) 3 Page - AXElite technology co. ltd |
|
3 / 11 page ![]() 3/11 Axelite Confidential Materials, do not copy or distribute without written consent. Rev.1.7 Sep.19, 2019 AX1008 ABSOLUTE MAXIMUM RATINGS (at TA=25°C) Characteristics Symbol Rating Unit DC Supply Voltage VIN -0.3 to 12 V Power Dissipation PD Internally Limited Storage Temperature TST -65 to +150 °C Operating Junction Temperature Range TOPJ -40 to +125 °C Maximum junction Temperature TMJ 150 °C ELECTRICAL CHARACTERISTICS (VIN = VEN=3.6V, TA =25°C, unless otherwise specified) Characteristics Symbol Conditions (Notes) Min. Typ. Max. Units Reference Voltage VREF IOUT=10mA, TJ=25°C, (VIN- VOUT) =1.5V 1.225 1.250 1.275 V Output Voltage (Fixed Version) VOUT IOUT=10mA, TJ = 25°C 2.7V≦VIN≦12V 1.175 1.200 1.225 V IOUT = 10mA, TJ = 25°C, 3V≦VIN≦12V 1.470 1.500 1.530 V IOUT = 10mA, TJ = 25°C, 3.3V≦VIN≦12V 1.764 1.800 1.836 V IOUT = 10mA, TJ = 25°C, 4V≦VIN≦12V 2.450 2.500 2.550 V IOUT = 10mA, TJ = 25°C, 4.8V≦VIN≦12V 3.235 3.300 3.365 V IOUT = 10mA, TJ = 25°C, 6.5V≦VIN≦12V 4.900 5.000 5.100 V Line Regulation IOUT=10mA, VOUT+1.5V<VIN<12V, TJ =25°C - 0.3 0.6 % Load Regulation VIN= VOUT+1.5V, 10 mA≦IOUT≦5A, TJ =25°C (Note 1,2) - 0.7 1.5 % Dropout Voltage Vo IOUT=5.0A ( VOUT=1% VOUT) - 1.3 1.5 V Current Limit VIN-VOUT=3V 5.1 - - A Minimum Load Current - 5 10 mA Ripple Rejection F=120Hz,COUT=10μf AX1008-XXX VIN=VOUT+3V - 60 70 dB Temperature Stability IOUT=10mA - 0.5 - % Thermal shutdown Temp (Over temperature protect) TSD - 145 - °C Thermal Shutdown Hysteresis TSH - 40 - °C Thermal Resistance Junction-to-Ambient (Note 3) θJA TO-252 - 55 - °C /W TO-263 - 45 - Thermal Resistance Junction-to-Case θJC TO-252 - 10 - °C /W TO-263 - 2.7 - Note 1: See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured at a constant junction temperature by low duty cycle pulse testing. Load regulation is measured at the output lead = 1/18” from the package. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |