| поискавой системы для электроныых деталей |
|
PBC датащи(PDF) 1 Page - Automatic Timing & Controls, Inc. |
|
|
|||||||||||||||||||||||||||||
PBC датащи(HTML) 1 Page - Automatic Timing & Controls, Inc. |
|
|
1 / 1 page ![]() 176 Diversified Electronics 800.727.5646 atcdiversified.com The PBC Series offers protection to three-phase equipment that is required to operate between two voltage limits. All three phases are monitored individually for a pre-selected UNDER and OVER VOLTAGE limit. With normal operating voltages applied, the internal relay will energize (PICK-UP). When the voltages on any or all phases fall outside the pre- set Over/Under trip points for longer than the Release delay, the relay will de-energize (DROP-OUT). When line conditions return to normal, the PBC Series Monitor automatically resets and the internal relay energizes. The LED fault indicators aid in set up and system trouble-shooting glow- ing on fault condition. The LED indicators have an immediate response to voltage conditions and operate independently of the relay. The HYSTERESIS in each unit provides a differential of 4% between the PICK-UP and DROP-OUT trip points. The PBC Series is UL Listed under UL File Number E55826. OPERATION SPECIFICATIONS OUTPUT RATING DPDT, 10Amps @ 240 VAC, Resistive; 360 VA @ 600 VAC, Inductive; 1/2 hp POWER REQUIRED Models Up to 300 VAC 7 VA, Max Models Over 300 VAC 6 VA, Max RESET Automatic HYSTERESIS 4% REPEAT ACCURACY 0.1% @ Fixed Condition INDICATORS LED Glows On Fault; (1) For Over, (1) For Under RESPONSE TIMES Operate 100 mSEC Release 0.5 SEC TEMPERATURE Operate 32° to +131°F (0° to +55°C) RATING Storage -49° to 185°F (-45° to +85°C) WEIGHT 20 oz. MODEL MAXIMUM ADJUSTABLE RANGES NUMBER VOLTAGE UNDER OVER PBC-120-ALE 155 VAC 90-120 120-150 PBC-230-ALE 275 VAC 185-240 208-265 PBC-400-ALE 485 VAC 325-385 415-475 PBC-440-ALE 550 VAC 390-480 440-540 PBC-480-ALE 570 VAC 400-490 460-560 PBC-575-ALE 700 VAC 500-610 540-690 All voltages referenced on this page are phase-to-phase, unless otherwise indicated. MODEL MAXIMUM ADJUSTABLE RANGES NUMBER VOLTAGE (Phases to Neutral) UNDER OVER PBC-120/208-ALE 268 VAC 90-120 120-150 PBC-220/380-ALE 450 VAC 185-220 220-255 PBC-277/480-ALE 565 VAC 235-277 277-320 All voltages referenced on this page are phase-to-phase, unless otherwise indicated. DELTA CONNECTED WYE CONNECTED 3-Phase Voltage Band Monitor DIMENSIONS (INCHES) IND. CONT. EQ 496Y WIRING |
Аналогичный номер детали - PBC |
|
Аналогичное описание - PBC |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |