| поискавой системы для электроныых деталей |
|
HT1647 датащи(PDF) 11 Page - Holtek Semiconductor Inc |
|
|
|||||||||||||||||||||||||||||
HT1647 датащи(HTML) 11 Page - Holtek Semiconductor Inc |
|
11 / 17 page ![]() HT1647 Rev. 1.30 11 November 10, 2005 Bias Generator The HT1647 bias voltage belongs to internal resistor type. It provides two kinds of bias option named 1/5 bias and 1/4 bias respectively. It is recommended to select 1/5 bias to fit TN-type, STN-type LCDs and select 1/4 bias to fit ECB-type LCDs. It also provides three kinds of bias current option by programming to suitably drive an LCD panel. The three kinds of bias current are large, middle, and small, respectively. Usually, large panel LCD can be excellently displayed by large bias current. Relatively, it consumes large current when LCD ON command is used. Small bias current provides low power consumption during On condition when the LCD is normally displayed. The following are the reference value table. VLCD Bias Large Bias Current Middle Bias Current Small Bias Current 4V 1/5 300 mA 100 mA40mA 4V 1/4 375 mA 125 mA50mA V R * V L C D * R V S S V 2 V 3 V 4 V 1 1 / 5 b i a s R V S S V 2 V 3 V 4 V 1 1 / 4 b i a s R R R R R R R R V D D V L C D V D D V L C D * T h e v o l t a g e a p p l i e d t o V L C D p i n m u s t b e l o w e r t h a n V D D * A d j u s t V R t o f i t L C D d i s p l a y , a t V D D = 5 V , V L C D = 4 V , V R = 1 5 k W ± 2 0 % V L C D * V R * Internal Resistor Type Bias Generator Configurations Interfacing Only six lines are required to interface with the HT1647. The CS line is used to initialize the serial interface circuit and to terminate the communication between the host controller and the HT1647. If the CS pin is set to 1, the data and command issued between the host controller and the HT1647 are first disabled and then initialized. Before issuing a mode command or mode switching, a high level pulse is required to initialize the serial inter- face of the HT1647. The DB0~DB3 are the 4-bit parallel data input/output lines. Data to be read or written or commands to be written have to pass through the DB0~DB3 lines. The RD line is the READ clock input. Data in the RAM are clocked out on the falling edge of the RD signal, and the clocked out data will then appear on the DB0~DB3 lines. It is recommended that the host controller read correct data during the interval between the rising edge and the next falling edge of the RD signal. The WR line is the WRITE clock input. The data, ad- dress, and command on the DB0~DB3 lines are all clocked into the HT1647 on the rising edge of the WR signal. There is an optional IRQ line to be used as an in- terface between the host controller and the HT1647. The IRQ pin can be selected as a timer output or a WDT overflow flag output by the S/W setting. The host con- troller can perform the time base or the WDT function by connecting with the IRQ pin of the HT1647. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |