| поискавой системы для электроныых деталей |
|
SC4808B-2MSTRT датащи(PDF) 18 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
SC4808B-2MSTRT датащи(HTML) 18 Page - Semtech Corporation |
|
18 / 28 page ![]() 18 2006 Semtech Corp. www.semtech.com SC4808B-2 POWER MANAGEMENT SOFT START During start up of the converter, the discharged output ca- pacitor and the load current have large supply current re- quirements. To avoid this a soft start scheme is usually implemented where the duty cycle of the regulator is gradu- ally increased from 0% until the soft start duration is elapsed. SC4808B-2 has an internal soft start circuit that limits the duty cycle for a duration approximated by the formula be- low. Also the soft start circuitry is activated if an over cur- rent condition occurs. After an over current condition, OUTA and OUTB are disabled and kept low for a duration of about 140µs. After the delay, the OUTA and OUTB are enabled while the soft start limits the duty cycle. If the over current condition persists, the soft start cycle repeats indefinitely. Approximate internal soft start duration can be calculated as below: () + × ≅ 1 R R 2 VREF Ramp T GND _ to _ CS SlopeComp _ Internal SoftStart SoftStart If longer soft start durations are required, the simple exter- nal circuit shown below can be implemented. R27 15k 200p C31 VCC R28 10 2.2u,16V C26 REF 0.1u,25V C33 R33 10k SYNC U4 SC4808 4 5 3 2 10 1 6 7 8 9 FB REF CS RC LUVLO SYNC GND OUTB OUTA VCC R23 56.2k Vin 56.2K Csoft start REF MOCD207 6 5 C40 NA R37 1k Approximate soft start duration can be calculated as be- low: 37 R C T SoftStart SoftStart × ≅ Application Information (Cont.) START UP SEQUENCE Initially during the power up, the SC4808B-2 is in under voltage lock out condition. As the Vcc supply exceeds the UVLO limit of the SC4808B-2, the internal reference, oscil- lator, and logic circuitry are powered up. The OUTA and OUTB drivers are not enabled until the line under voltage lock out limit is reached. At that point, once the FB pin is above 1.5V, soft start circuitry starts the out- put drivers, and gradually increases the duty cycle from 0%. The soft start duration is internally set (see formula in Soft Start section). As the output voltage starts to increase, the error signal from the error amplifier starts to decrease. If isolation is required, the error amplifier output can drive the LED of the opto isolator. The output of the opto is connected in a common emitter configuration with a pull-up resistor to a reference voltage connected to the FB pin of the SC4808B- 2. The voltage level at the FB pin provides the duty cycle necessary to achieve regulation. If an over current condition occurs, the outputs are dis- abled and after a soft start delay time of about 100µs, the softstart sequence mentioned above is repeated. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |