| поискавой системы для электроныых деталей |
|
TLV1921 датащи(PDF) 13 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TLV1921 датащи(HTML) 13 Page - Texas Instruments |
|
13 / 26 page ![]() The following is a summary of input voltage range conditions and the outcomes: 1. When both IN- and IN+ are within the common mode voltage range: a. If IN- is greater than IN+ and the offset voltage, the output is low. b. If IN- is less than IN+ and the offset voltage, the output is high. c. If IN- is equal to IN+, the output state is technically indeterminite and output state is determined by the random polarity of the internal offset votlage. 2. When IN- is higher than the common mode voltage range and IN+ is within the common mode voltage range, the output is low. 3. When IN+ is higher than the common mode voltage range and IN- is within the specified input voltage range, the output is high 4. When IN- and IN+ are both outside the common mode voltage range, the output is low, regardless of which input is greater. Operating outside the common mode range causes changes in specifications such as propagation delay and input bias current. Likewise, there is a recovery time when re-entering the common mode voltage range. 6.4.1.2 Fail-Safe Inputs Fail-safe is defined as maintaining the same high input impedance when V+ is unpowered or within the recommended operating ranges and is not damaged. The TLV192x inputs are fault tolerant up to 65V independent of V+. The fail-safe input voltage is any value between 0V and 65V from GND, even while V+ is zero or ramping up or down. This feature avoids power sequencing issues as long as the input voltage range and supply voltage are within the specified range. The fail-safe inputs have snapback ESD protection from each pin to GND which allows these pins to exceed the supply voltage (V+) up to 65V. If input voltages exceed 65V, an external clamp is required. Likewise, negative voltages on the inputs are ESD clamped to GND and need to be limited to less than -0.2V. If the inputs are to be connected to a low impedance source, such as a power supply or buffered reference line, add a current-limiting resistor in series with the input to limit any transient currents the clamps conduct. The current needs to be limited to 10mA or less. This series resistance can be part of any resistive input dividers or networks. 6.4.1.3 Unused Inputs If a channel is not used, DO NOT tie the inputs together. Due to the high equivalent bandwidth and low offset voltage, tying the inputs directly together causes high frequency oscillations as the device triggers on it's own internal wideband noise. Instead, the inputs are to be tied to any available voltage that resides within the specified input voltage range and provides a minimum of 50mV differential voltage. For example, one input is grounded and the other input connected to a reference voltage, or even (V+). 6.4.2 Open-Drain Output The TLV192x features a open-drain (also commonly called open collector) sinking-only output stage enabling the output logic levels to be pulled-up to an external voltage from 0 V up to 65V, independent of the comparator supply voltage (V+). The open-drain output also allows logical OR'ing of multiple open drain outputs and logic level translation. TI recommends setting the pull-up resistor current to less than 100 uA to optimize VOL logic levels. Lower pull-up resistor values help increase the risetime, but at the expense of increasing VOL and higher power dissipation. The risetime is dependent on the time constant of the total pull-up resistance and total load capacitance. Large value pull-up resistors (>1 MΩ) create an exponential rising edge due to the output RC time constant and increase the risetime. Directly shorting the output to the pull-up voltage results in thermal runaway and eventual device destruction at high (>65V) pull-up voltages. If output shorts are possible, a series current limitng resistor is recommended to limit the power dissipation. Shorting the output to V+ can eventually destroy the device. Unused open drain outputs can be left floating, or tied to the GND pin if floating pins are not desired. www.ti.com TLV1921, TLV1922 SNOSDG9 – DECEMBER 2024 Copyright © 2024 Texas Instruments Incorporated Submit Document Feedback 13 Product Folder Links: TLV1921 TLV1922 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |