3 / 8 page

3 of 8
RF2374
Rev A0 DS070705
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
Parameter
Specification
Unit
Condition
Min.
Typ.
Max.
Power Supply
Voltage (VCC)3
V
Gain Select Low
0.8
V
High Gain mode.
Gain Select<0.8V, VREF=3V
Gain Select High
1.8
V
Low Gain mode.
Gain Select>1.8V, VREF=0V
Power Down
0
5
μAGain Select<0.8V, VREF=0V, VCC=3.0V
Bias note: Due to the presence of ESD protection circuitry on the RF2374, the maximum allowable collector bias voltage (pin 6) is 4.0V. Higher
supply voltages such as 5V are permissible if a series resistor is used to drop VCC to <4.0V for a given ICC.