| поискавой системы для электроныых деталей |
|
MP1519 датащи(PDF) 6 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP1519 датащи(HTML) 6 Page - Monolithic Power Systems |
|
6 / 8 page ![]() MP1519 – 1X, 1.5X, 2X CHARGE PUMP 4 WHITE LED DRIVER MP1519 Rev. 1.9 www.MonolithicPower.com 6 7/27/2006 MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited. © 2006 MPS. All Rights Reserved. TM APPLICATION INFORMATION COMPONENT SELECTION Startup When power is applied to the BATT, driving EN high will enable the MP1519. The MP1519 begins by checking for open LEDs and determining the optimum charge pump mode. The lowest charge pump mode that allows the programmed LED current in all LEDs is set. This will occur during initial turn-on or during analog mode and burst mode dimming. Shutdown Driving EN low for more than 30µs will disable the MP1519. For safety the MP1519 runs a small supervisory circuit in standby to protect the charge pump output LEDC. The circuit shuts down when the charge pump output returns to zero volts (this can take a few seconds). The MP1519 is in true shutdown mode when LEDC is zero and the 30µs time interval has passed. The supply current should be less than 1µA. Setting the LED Current The LED regulation current is set through the resistor R1 (refer to the typical application circuit on page 1). The voltage across R1 is fixed at 1.25V, and the current through that resistor sets the current through the LEDs. Figure 2 shows LED Current (ILED) vs. R1 with VBATT = 3.6V. 25 20 15 10 5 0 0 5 10 15 20 Figure 2—ILED vs. R1 Choose R1 for the desired LED current according to the equation: LED I 31.25 R1 = Where R1 is in kΩ, and ILED is in mA. Suitable values for R1 are greater than 1.2kΩ. Soft-Start During startup and mode switching, an internal soft-start prevents excessive input current, preventing excessive loading of the battery or input power source. Burst Mode Dimming To dim the part using burst mode, drive EN with a PWM signal. Each time EN is driven high, the MP1519 goes through the initial startup routine and checks for open LEDs, and the charge pump step-up mode is reset. When EN goes low, the LED current immediately goes to zero. After EN is held low for 30µs or longer, and LEDC falls below GND, the MP1519 operating current drops below 1µA to improve battery life. Maintain the frequency of the PWM signal between 50Hz and 50KHz. Going above 50KHz the accuracy of the PWM signal will be degraded due to the startup time, and below 50Hz, the LED flicker will be evident to the eye. Ideally, the LED current increases proportionally with the duty cycle of the PWM signal and is independent of the dimming frequency. Analog Mode Dimming Analog dimming can be accomplished with the circuit in Figure 3. The circuit provides 1mA to 15mA dimming with VDC = 0 to 3V. The minimum LED current the MP1519 can regulate is approximately 1mA. LEDC Do not drive or force LEDC as it may be shorted to ground or may be pumped down by the controller in the MP1519 at any time. Excessive capacitance on the LEDC node can cause the internal controller to time out before the charge pump can be ready. Missing the timeouts will cause excessive pumping and a loss of efficiency. The MP1519 requires C1 and C2 be of the same value and type. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |