18 / 50 page

- 18 -
© Andigilog, Inc. 2006
www.andigilog.com
October 2006 - 70A06010
aSC7621
A remote diode temperature reading register will return a value of 8000h if the remote diode pins are not used by the board
designer or is not functioning properly. This reading will cause the zone limit bits (bits 4 and 6) in the Interrupt Status
Register (41h) and the remote diode fault status bit (bits 6 and 7) in the Interrupt Status Register 2 (42h) to be set. These
registers are read-only – a write to these registers has no effect.
Digital Output (2’s Complement)
High Byte
Low Byte
Temperature
10-Bit Resolution
Ignore
+125°C
0111
1101
.00
XX
XXXX
+100°C
0110
0100
.00
XX
XXXX
+50°C
0011
0010
.00
XX
XXXX
+25°C
0001
1001
.00
XX
XXXX
+10°C
0000
1010
.00
XX
XXXX
+1.75°C
0000
0001
.11
XX
XXXX
+0.25°C
0000
0000
.01
XX
XXXX
0°C
0000
0000
.00
XX
XXXX
-1.75°C
1111
1110
.01
XX
XXXX
-55°C
1100
1001
.00
XX
XXXX
Table 3 Relationship between Temperature and 2’s Complement Digital Output, -55°C to +125°C
Digital Output (2’s Complement)
High Byte
Low Byte
Temperature
10-Bit Resolution
Ignore
0°C
0000
0000
.0000
00
XX
-0.015625°C
1111
1111
.1111
11
XX
-0.03125°C
1111
1111
.1111
10
XX
-0.0625°C
1111
1111
.1111
00
XX
-0.125°C
1111
1111
.1110
00
XX
-0.25°C
1111
1111
.1100
00
XX
-0.5°C
1111
1111
.1000
00
XX
-1.0°C
1111
1111
.0000
00
XX
-1.75°C
1111
1110
.0100
00
XX
-2.0°C
1111
1110
0000
00
XX
-25.0°C
1110
0111
0000
00
XX
-100°C
1001
1100
0000
00
XX
-127°C
1000
0001
0000
00
XX
Table 4 PECI Temperature Format