21 / 28 page ![]() AD7366/AD7367 Rev. 0 | Page 21 of 28 SHUTDOWN MODE Shutdown mode is intended for use in applications where slow throughput rates are required. Shutdown mode is suited to applications where a series of conversions performed at a relatively high throughput rate are followed by a long period of inactivity and thus, shutdown. When the AD7366/AD7367 is in full power-down, all analog circuitry is powered down. The falling edge of CNVST initiates the conversion. The BUSY output subsequently goes high to indicate that the conversion is in progress. Once the conversion is completed, the BUSY output returns low. If the CNVST signal is at logic low when BUSY goes low then the part enters shutdown at the end of the conversion phase. While the part is in shutdown mode the digital output code from the last conversion on each ADC can still be read from the DOUT pins. To read the DOUT data, CS must be brought low as described in the Serial Interface section. The DOUT pins return to three-state once CS is brought back to logic high. To exit full power-down and to power up the AD7366/AD7367, a rising edge of CNVST is required. After the required power-up time has elapsed, CNVST may be brought low again to initiate another conversion, as shown in Figure 24 (see the Power-Up Times section for power-up times associated with the AD7366/ AD7367). POWER-UP TIMES The AD7366/AD7367 have one power down mode, which has already been described in detail in the Shutdown Mode section. This section deals with the power-up time required when coming out of this mode. It should be noted that the power-up times (as explained in this section) apply with the recommended capaci- tors in place on the DCAPA and DCAPB pins. To power up from shutdown, CNVST must be brought high and remain high for a minimum of 70 μs, as shown in Figure 24. When power supplies are first applied to the AD7366/AD7367, the ADC can power up with CNVST in either the low or high logic state. Before attempting a valid conversion, CNVST must be brought high and remain high for the recommended power- up time of 70 μs. Then CNVST can be brought low to initiate a conversion. With the AD7366/AD7367 no dummy conversion is required before valid data can be read from the DOUT pins. If it is intended to place the part in shutdown mode when the supplies are first applied, then the AD7366/AD7367 must be powered up and a conversion initiated. However, CNVST should remain in the logic low state and when the BUSY signal goes low, the part enters shutdown. Once supplies are applied to the AD7366/AD7367, sufficient time must be allowed for any external reference to power up and to charge the various reference buffer decoupling capacitors to their final values. BUSY SCLK SERIAL READ OPERATION CS 1 12 tCONVERT t3 t2 ENTERS SHUTDOWN tPOWER-UP CNVST Figure 24. Autoshutdown Mode for AD7366 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |