| поискавой системы для электроныых деталей |
|
TMF8701 датащи(PDF) 28 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
TMF8701 датащи(HTML) 28 Page - OSRAM GmbH |
|
28 / 66 page ![]() Datasheet, Public Page 27 [v2-00] 2023-Feb-21 Document Feedback TMF8701 − Register Description Note(s): 1. At the end of the transaction of read a quarter, the contents of the registers from 0x20-0x9F will be automatically updated, and the contents of registers REGISTER_CONTENTS and TID will be updated. 2. At the end of a TDC, the TDC number will also auto increment. 0x30 Enable histogram readout; the internal state machine will stop when a histogram (e.g. calibration) is available and wait for readout by the host. If the selected histogram is readout, the host shall continue the state machine by sending command 0x32 cmd_data3 = Bitmask for the histograms to be readout: • Always set bit 0 to ‘0’ • Set bit 1 to get electrical calibration histograms • Set bit 2 to get optical calibration histogram • Always set bit 3 to ‘0’ • Set bit 4 to get proximity histograms • Always set bit 5 and 6 to ‘0’ • Set bit 7 to get distance measurement histograms cmd_data2 = Set to 0x00 cmd_data1 = bitmask for pileup correct histograms readout: • Set bit 0 to get pileup corrected distance measurement histograms • Set bit 1 to get pileup corrected sum histogram • Set bit 2 to get pileup corrected proximity histogram • Always set bit 3-7 to 0 cmd_data0 = Set to 0x00 Once above bitmask is set, the device is programed to stop when the histogram is available. Set command=0x04 to actually perform the measurement. 0x32 After the host has readout the histogram, continue with internal processing. 0x47 Read out serial number – results see section Serial Number Readout – If Register register_contents=0x47 0x80 … 0x93 Read 1 quarter of one histogram - copy histogram bits[4:2] to select TDC0… TDC5, quarter bits[1:0] into 0x20... 0x9f (1), (2) 0xff Stop whatever you are doing as soon as possible and reenter the idle state. The current state will not be interrupted and will require leaving the current state processing to take effect. This command will stop continuous measurement. 0x10: COMMAND Field Name Reset Type Description |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |