| поискавой системы для электроныых деталей |
|
IPA датащи(PDF) 2 Page - Sensata Technologies, Inc. |
|
|
|||||||||||||||||||||||||||||
IPA датащи(HTML) 2 Page - Sensata Technologies, Inc. |
|
2 / 9 page ![]() Page 2 www.sensata.com Copyright © 2020 Sensata Technologies, Inc. SINGLE POLE (ONE HANDLE) 1.260 [32.00] .640 MAX. [16.26] 2X 6-32 THREAD .165 MAX. [4.19] .535 [13.59] 1.654 [42.01] .982 [24.94] O N O F F 1.732 [43.99] .098 [2.49] 60 1.988 MAX. [50.50] .635 [16.13] LINE .228 [5.79] .787 [19.99] 1.260 [32.00] .551 [14.00] 2X .157 [3.99] Mounting Detail Notes: 1. Tolerance ± .015 [.38] unless noted. Dimensions in brackets [ ] are millimeters. 2. Main circuit breaker terminals are stationary male push-on type: .248 [6.30] wide x .031 [.787] thick x .474 [12.00] long, or screw type: M4 x .354 [8.99] wide x .031 [.787] thick x .474 [12.00] long. Construction Series and series with auxiliary switch available in various delays and combinations. Auxiliary and Alarm Switch When supplied shall be S.P.D.T. configuration with a maximum rating of 3.0 amperes, 250Vac resistive load. Gold contacts are rated at .100 amperes, 125Vac resistive load. Moisture Resistance Meet all the requirements of MIL-PRF-55629 when tested in accordance with Method 106 of MIL-STD-202. Salt Spray (Corrosion) Meet the requirements of MIL-PRF-55629 when tested in accordance with Method 101 of MIL-STD-202. Shock Circuit protectors shall not trip when tested per MIL-STD-202, Method 213, Test Condition B with 100% rated current applied to delayed units and 80% rated current to instantaneous units. Units with auxiliary switches will withstand 30G max. Vibration Circuit protectors shall not trip when vibrated per MIL-STD-202, Method 201, Test Condition A with 100% rated current applied to delayed units and 80% rated current to instantaneous units. Recommended Torque Specifications Component Torque (in-lbs) 6-32 Mounting Inserts 6 to 8 M3 Mounting Screws 4 to 5 M4 Terminal Screws 10 to 12 Approximate Weight Per Pole Ounces Grams 1.7 48 Inrush Pulse Tolerance Delay Pulse Tolerance 61, 62, 600 8 times rated current 61F, 62F, 600F 12 times rated current Where applicable, mechanical support must be provide to the terminals when applying torque Comparison of inrush pulse tolerance is with and without the inertia delay feature for each of the 50/60 Hz delays. Pulse tolerance is defined as a single pulse of half sine wave peak current amplitude of 8 milliseconds duration that will not trip the circuit protector |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |