| поискавой системы для электроныых деталей |
|
PLC датащи(PDF) 3 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
PLC датащи(HTML) 3 Page - Christian Bürkert GmbH & Co. KG |
|
3 / 11 page ![]() Type 8312 3 | 11 Visit product website 1. General Technical Data Product properties Material Non wetted parts Housing Stainless steel 1.4305 (303) Wetted parts Process connection • Ceramic version: stainless steel 1.4305 (303) • Metallic G or NPT version: stainless steel 1.4571 (316Ti) • Metallic clamp version: stainless steel 1.4435 (316L) Measurement element • Ceramic version: ceramic Al 2O3 (96 %) • Metallic version: stainless steel 1.4435 (316L) Seal • Ceramic version: FPM (FFPM on request) • Metallic version: none Dimensions Detailed information can be found in chapter “3. Dimensions” on page 6. Surface quality For clamp connection Ra < 0.8 µm Measurement technology • Ceramic thick film strain gauge • Metallic thin film strain gauge Measured variable Relative pressure (absolute pressure on request) Measuring range - 1…5 or 0…0.25; 1; 1.6; 2.5; 4.0; 6.0; 10.0 or 16.0 bar Detailed information can be found in chapter “6.3. Ordering chart” on page 9. Compensated ambient temperature range (T amb.) - 20…+ 85 °C (- 4…+ 185 °F) Monitoring • Measuring circuit – Underrange (freely selectable lower limit) – Overrange (freely selectable upper limit) • Probe short circuit • Probe break Weight 95 g with process connection G ¼" Performance data Temperature coefficient (Tc) In compensated T° amb. range Average Tc of zero • Ceramic version: ≤ 0.02 % / °C typical, ≤ 0.04 % / °C max. • Metallic version: – ≤ 0.03 % / °C typical, ≤ 0.05 % / °C max. for measuring ranges ≤ 0.4 bar – ≤ 0.02 % / °C typical, ≤ 0.04 % / °C max. for measuring ranges > 0.6 bar Average Tc of measuring span • Ceramic version: ≤ 0.02 % / °C typical, ≤ 0.04 % / °C max. • Metallic version: ≤ 0.02 % / °C typical, ≤ 0.04 % / °C max. Thermal hysteresis • Ceramic version: ≤ ± 0.4 % of measuring span • Metallic version: – ≤ ± 0.5 % of measuring span (in compensated temperature range) – ≤ ± 1 % of measuring span for range 0…0.25 bar Zero offset ≤ 0.3 % of measuring span Cycle time 1 ms Measuring resolution 12 Bit Overload limit 3 x measuring span Burst pressure 4 x measuring span Detailed information on burst pressure can be found in chapter “6.3. Ordering chart” on page 9. Measurement deviation Related to characteristic curve: ≤ 0.5 % of measuring span (limit point setting) Hysteresis • Ceramic version: ≤ 0.2 % of measuring span • Metallic version: ≤ 0.1 % of measuring span Repeatability • Ceramic version: ≤ 0.1 % of measuring span • Metallic version: ≤ 0.05 % of measuring span |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |