| поискавой системы для электроныых деталей |
|
8137 датащи(PDF) 4 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
8137 датащи(HTML) 4 Page - Christian Bürkert GmbH & Co. KG |
|
4 / 12 page ![]() Type 8137 4 | 12 Visit product website DC reverse polarity protection Yes Output signal 4…20 mA/HART Signal resolution 0.3 µA Range of the output signal 3.8…20.5 mA/HART (default setting) Load resistor (U n - Umin.)/0.022 A Fault signal Current output: mA value unchanged, 20.5 mA, 22 mA or < 3.6 mA (adjustable) Max. output current 22 mA Residual ripple (at DC) • For 9.6 V < U n < 18 V: ≤ 0.7 Veff (16…400 Hz) • For 18 V < U n < 35 V: ≤ 1.0 Veff (16…400 Hz) Voltage supply cable • Cable diameter: 5…9 mm • Wire cross-section (spring-loaded terminals): – massive wire, stranded wire: 0.2…2.5 mm2 (AWG 24…14) – stranded wire with end sleeve: 0.2…1.5 mm2 (AWG 24…16) Medium data Process temperature - 40 °C…+ 130 °C (- 40 °F…266 °F) Process pressure Vessel pressure: - 1…40 bar (- 100…4000 kPa/- 14.5…580 psi) or according to flange rules Dielectric constant (min.) εr > 1.6 Process/Port connection & communication Process connection • Thread G 1½" or NPT 1½" • Flange DN 50 or DN 100 DIN 2501, 2" or 4" ANSI B16.5 Electrical connection Cable glands M20 x 1.5 Approvals and Certificates Standards Degree of protection according to IEC/EN 60529 IP66/IP67 with M20 x 1.5 gland mounted and tightened Overvoltage category according to IEC 61010-1 Category III Protection class according to IEC 61010-1 Class III Directives CE directives The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applica- ble) NAMUR recommendations • NE21 – Electromagnetic compatibility of equipment • NE43 – Signal level for fault information from measuring transducers • NE53 - Compatibility of field devices and display/adjustment components • NE107 - Self-monitoring and diagnosis of field devices Approvals ATEX EN 60079-0, EN 60079-11, EN 60079-26 Detailed information can be found in chapter “2.1. ATEX-Certification” on page 5. Environment and installation Ambient temperature Operation and storage: - 40 °C…+ 80 °C (- 40 °F…+ 176 °F) Relative air humidity 20…85 %, without condensation Height above sea level • By default: max. 2000 m • With connected overvoltage protection: max. 5000 m Pollution degree Degree 4 (when used with fulfilled housing protection) 1.) Outside the specified beam angle, the energy level of the radar signal is 50 % (- 3 dB) less 2.) Time span after a sudden measuring distance change by max. 0.5 m in liquid applications, max 2 m with bulk solids applications, until the output signal has taken for the first time 90 % of the final value (IEC 61298-2) 3.) Already included in the measuring deviation |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |