| поискавой системы для электроныых деталей |
|
2012 датащи(PDF) 19 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
2012 датащи(HTML) 19 Page - Christian Bürkert GmbH & Co. KG |
|
19 / 21 page ![]() Type 8652 19 | 21 Visit product website Circuit function Orifice Q Nn value 1.) Air Pressure range Switching times Voltage/ Frequency Article no. 2.) incl. screw Opening Closing [mm] [l/min] [bar] [ms] [ms] [V/Hz] N (CF N) 5/3-way solenoid valve With manual override In middle position ports 2 and 4 exhausted 14 12 4 2 5 1 3 4 300 Vac....10 3.) 3…10 20 20 24 V DC 301381 Dummy valve – – – – – – 335779 1.) Approx. 3 % flow reduction for Hot Swap function 2.) The valves are components or spare parts of the Type 8652 Valve Terminal and can only be used on the Type 8652 Valve Terminal. 3.) Separate auxiliary pilot air min. 3 bar. Please observe the pilot pressure table in the operating instructions Type 8652 . Solenoid valve Type 6534 SIA variant (2nd port for shutdown) Note: Further information about this product version can be found in chapter “7.3. Valves Type 6534 for safety-related shut-off, SIA variant (optional)” on page 14. Circuit function Orifice Q Nn value 1.) Air Pressure range Switching times Voltage/ Frequency Article no. 2.) incl. screw Opening Closing [mm] [l/min] [bar] [ms] [ms] [V/Hz] C (CF C) 2 x 3/2-way solenoid valve Servo-controlled Normally closed 4 1 5 14 2 1 3 12 4 270 l/min Vac....10 3.) 3…10 15 15 24 V DC 338802 H (CF H) 5/2-way solenoid valve Servo-controlled Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. 14 12 4 2 5 1 3 4 290 l/min Vac....10 3.) 3…10 20 25 24 V DC 338805 L (CF L) 5/3-way solenoid valve In middle position all ports locked 14 12 4 2 5 1 3 4 275 l/min Vac....10 3.) 3…10 15 15 24 V DC 346830 1.) Approx. 3 % flow reduction for Hot Swap function 2.) The valves are components or spare parts of the Type 8652 Valve Terminal and can only be used on the Type 8652 Valve Terminal. 3.) Separate auxiliary pilot air min. 3 bar. Please observe the pilot pressure table in the operating instructions Type 8652 . |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |