| поискавой системы для электроныых деталей |
|
3321 датащи(PDF) 3 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
3321 датащи(HTML) 3 Page - Christian Bürkert GmbH & Co. KG |
|
3 / 29 page ![]() Type 3361 3 | 29 Visit product website 1. General technical data Note: • AG2: Actuator size 2 with a nominal force of 1300 or 2500 N for seat size 3…50 • AG3: Actuator size 3 with a nominal force of 7700 or 10000 N for seat size 40…100 Product properties Dimensions Detailed information can be found in chapter “4. Dimensions” on page 8. Material Detailed information can be found in chapter “3. Materials” on page 6. Design Globe control valve Nominal diameter DN 10…100, NPS ⅜…4 Safety setting in case of power failure With SAFEPOS energy-pack: open, closed or freely programmable Without SAFEPOS energy-pack: blocked in last position Flow direction Against closing direction (below seat) Controller version Position controller or process controller Weight Actuator depending on version up to: AG2: 5.5 kg AG3: 16 kg (Total weight including valve body depending on port connection) Performance data Operating pressure 0…25 bar(g) (see “5.1. Fluidic data” on page 16) Vacuum version up to – 0.9 bar(g) (optional) Nominal pressure PN 25 (DIN EN 1333), Class 150 (DIN EN 1759) K VS value 0.1…140 m3/h (see “5.1. Fluidic data” on page 16) Flow characteristic Linear or equal percentage (see “5.1. Fluidic data” on page 16) Seat leakage (DIN EN 60534 - 4) Class III, IV and VI (see “5.1. Fluidic data” on page 16) Closing time1.) AG2: 3.3…6.6 s AG3: 8.7…12.0 s (Depending on travel speed, stroke and operating conditions) Theoretical rangeability Up to 50:1 (see “5.1. Fluidic data” on page 16) Travel speed1.) 6 mm/s (for AG2 actuator force 1300 N) 4 mm/s (for AG2 actuator force 2500 N) 3 mm/s (for AG3 actuator force 7700 N and 10000 N) (Depending on operating conditions) Dead band of the position control ± 0.1 % Electrical data Operating voltage 24 V DC ± 10 % (max. residual ripple 10 %) Operating current1.) AG2: Max. 3 A (at max. load and including 1 A charging current of the optional SAFEPOS energy-pack). At minimum operating temperature additionally 2 A AG3: Max. 5 A (at max. load and including charging current of the optional SAFEPOS energy-pack). At minimum operating temperature additionally 6 A Protection class (DIN EN 61140) 3 Duty cycle 100 % Standby consumption1.) 2…5 W Communication and control Standard signal (analogue) Setpoint: 0/4…20 mA, 0…5/10 V and digital input (further inputs and outputs optional, see “5.3. Electrical control and interfaces” on page 22) Fieldbus (digital) Bürkert system bus (büS) CANopen (optional) EtherNet/IP, PROFINET, Modbus/TCP (optional via integrated gateway) Media data Process medium Steam, neutral gases, water, alcohols, oils, fuels, hydraulic fluids, salt solutions, lyes, organic solvents, oxygen (optional) Medium temperature – 40…+ 230 °C (see “5.2. Operating limits” on page 19) Viscosity Up to 600 mm2/s |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |