| поискавой системы для электроныых деталей |
|
8006 датащи(PDF) 3 Page - Christian Bürkert GmbH & Co. KG |
|
|
|||||||||||||||||||||||||||||
8006 датащи(HTML) 3 Page - Christian Bürkert GmbH & Co. KG |
|
3 / 15 page ![]() Type 3285 3 | 15 Visit product website 1. General technical data 1.1. General Product properties Dimensions Further information can be found in chapter “4. Dimensions” on page 7. Material Further information can be found in chapter “3.2. Material specifications” on page 6. Valve body Brass or stainless steel Seal • NBR for liquids • EPDM for liquids and special gases (e. g. ammonia, acetylene) • FKM for neutral gases Seat sealing Technical ceramics Design • Disc On/Off valve • Disc control valve Connection nominal diameter DN 15… DN 25, NPS ½…1 Safety setting in case of power failure With capacitive buffer module as accessory, see chapter “4.2. Capacitive buffer module” on page 8. Flow direction Above seat Controller variant Standard On/Off, standard control valve, position controller or process controller Weight ~ 0.8 kg (DN 8)…1.5 kg (DN 25) Status display LED (Refer to the instruction manual for more information.) Performance data Typical values of positioning behaviour1.) Dead band of the position control ± 0.5 % (corresponds to setting range 1:100) Closing time 4 s Operating pressure 0…6 bar(g) (see chapter “6.2. Pressure range” on page 10) Vacuum version (up to - 0.9 bar(g)) (optional) K VS value 1.8…9.6 m³/h (see chapter “6.2. Pressure range” on page 10) Electrical data Operating voltage 24 V DC ± 10 % (max. residual ripple 10 %) Duty cycle Up to 100 % (depending on medium and ambient temperature) Power consumption < 1 W in holding position Max. 12 W (depending on motor control) Medium data Operating medium Neutral gases, liquids Medium temperature • EPDM (seal material): - 30 °C…+ 70 °C • FKM, NBR (seal material): 0 °C…+ 70 °C Viscosity Max. 80 mm²/s (cSt) Process/Port connection & communication Port connection Threaded connection • G (EN ISO 228 - 1) • NPT (ASME B 1.20.1) Communication and control Standard signal (analogue) Setpoint: 0/4…20 mA, 0…5/10 V and digital input, see chapter “1.2. Electrical control and inter- faces” on page 4. Fieldbus (digital) • Bürkert system bus (büS) • CANopen (optional) EDIP Field device for integration into the EDIP platform via Bürkert system bus (büS) Further information can be found in chapter “8.2. Bürkert Communicator Software” on page 13. Approvals and conformities Degree of protection IP50 North America (USA/Canada) Further information can be found in chapter “2.4. North America (USA/Canada)” on page 5. Drinking water Further information can be found in chapter “2.5. Drinking water” on page 5. Others Further information can be found in chapter “2.6. Others” on page 5. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |