| поискавой системы для электроныых деталей |
|
PDIUSBH12 датащи(PDF) 15 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PDIUSBH12 датащи(HTML) 15 Page - NXP Semiconductors |
|
15 / 28 page ![]() Philips Semiconductors Product specification PDIUSBH12 USB 2-port hub 1999 Jul 22 15 Set Endpoint Status Command : 40–4Dh Data : Write 1 byte A stalled control endpoint is automatically unstalled when it receives a SETUP token, regardless of the content of the packet. If the endpoint should stay in its stalled state, the microcontroller can re-stall it. When a stalled endpoint is unstalled (either by the Set Endpoint Status command or by receiving a SETUP token), it is also re-initialized. This flushes the buffer and if it is an OUT buffer it waits for a DATA 0 PID, if it is an IN buffer it writes a DATA 0 PID. Even when unstalled, writing Set Endpoint Status to ‘0’ initializes the endpoint. 76 5 4 3 2 X 1 0 0 POWER ON VALUE STALLED RESERVED XX XX XX SV00834 Stalled A ‘1’ indicates the endpoint is stalled. Acknowledge Setup Command : F1h Data : None The arrival of a SETUP packet flushes the IN buffer and disables the Validate Buffer and Clear Buffer commands for both IN and OUT endpoints. The microcontroller needs to re-enable these commands by the Acknowledge Setup command. This ensures that the last SETUP packet stays in the buffer and no packet can be sent back to the host until the microcontroller has acknowledged explicitly that it has seen the SETUP packet. The microcontroller must send the Acknowledge Setup command to both the IN and OUT endpoints. Hub Commands Hub commands are used to report connectivity and power status between the hub and the host. These commands allow the host to enable each port individually and get any change of status such as new connectivity information. Clear/Set Port Feature Command : E0–E1h (Clear) and E8h–E9h (Set) Data : Write 1 byte The data written in the data phase is the feature code described in Table 4. When the controller receives a Set Feature or a Clear Feature request, there are two possibilities: The request applies to port 1, the embedded port. In this case the request should be handled internally by the controller. If the request applies to ports 2 and 3, the controller should translate the request into a Set Feature or Clear Feature command towards the PDIUSBH12. When the PDIUSBH12 is configured in mode 0, there is only one power switch output and one overcurrent input. This means that the F_PORT_POWER and C_PORT_OVERCURRENT features are not port specific. For these features, any of the Set / Clear Feature commands can be used. The specific port assignment is ignored. When the PDIUSBH12 is configured in mode 1, there is still only one power switch output but there are two individual overcurrent input pins corresponding to each port. This means that the F_PORT_POWER feature is port specific and the C_PORT_OVERCURRENT feature is not port specific. Setting the F_PORT_POWER feature turns the power on when it is off and turns the overcurrent detection on only when the power is already on. This allows it to have a short period of overcurrent condition at the moment that power is switched on. For this reason, the F_PORT_POWER feature needs to be set twice. Clearing this feature turns both the power and the overcurrent detection off. Table 4. FEATURE FEATURE CODE SET CLEAR F_PORT_ENABLE 0 Enables a port Disables a port F_PORT_SUSPEND 1 Suspends a port Resumes a port FC_PORT_RESET 2 Resets a port Clears a port Reset Change bit F_PORT_POWER 3 Powers all ports Unpowers all ports C_PORT_CONNECTION 4 – Clears a port Connection Change bit C_PORT_ENABLE 5 – Clears a port Enable Change bit C_PORT_SUSPEND 6 – Clears a port Suspend Change bit C_PORT_OVERCURRENT 7 – Clears a port (Mode 1) or hub (Mode 0) Overcurrent Change bit |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |