| поискавой системы для электроныых деталей |
|
PDIUSBH11 датащи(PDF) 16 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PDIUSBH11 датащи(HTML) 16 Page - NXP Semiconductors |
|
16 / 26 page ![]() Philips Semiconductors Product specification PDIUSBH11 Universal Serial Bus Hub 1997 Aug 01 16 Host Requests SetFeature PORT_RESET Reinitialize the embedded function and set the Reset Change bit to indicate that the reset has completed. Reset the Enable Status bit, enable the embedded function and set its address to 0 by the Set embedded function Address / Enable command. Disable the embedded function interrupt endpoint by the Set Endpoint Enable command. SetFeature PORT_ENABLE Enable the function by the Set embedded function Address / Enable command. Set the Enable Status bit. SetFeature PORT_SUSPEND Disable the function by the Set embedded function Address / Enable command. Reset the Enable Status bit and set the Suspend Status bit. ClearFeature PORT_ENABLE Disable the function by the Set embedded function Address / Enable command. Reset the Enable Status bit. ClearFeature PORT_SUSPEND Enable the function by the Set embedded function Address / Enable command. Set the Enable Status bit, reset the Suspend Status bit; set the Resume Status Change bit to indicate that the resume has completed. ClearFeature any Change Indicator Clear the corresponding status change bit. Babbling Condition When the embedded function causes a babbling condition, the function is automatically disabled by the PDIUSBH11. As soon as the micro controller detects the babbling error, it must set the Enable Status Change bit and reset the Enable Status bit. Remote WakeUp There are three scenarios a remote wakeup can occur. The following describes the course of actions for each of the cases: 1. The device is not suspended and the embedded port is suspended – Enable back the function by setting the enable bit in the Set Address/Enable register and update the following status bits in the micro–controller program: reset the Suspend Status bit, set the Enable Status bit and set the Suspend Status Change bit. 2. The device is suspended and the embedded port is suspended. – Send an upstream Resume using the Send Resume command, enable back the function by setting the enable bit in the Set Address/Enable register and update the following status bits in the micro–controller program: reset the Suspend Status bit, set the Enable Status bit and set the Suspend Status Change bit. 3. The device is suspended and the embedded port is enabled – Send an upstream resume using the Send Resume command RECOMMENDED OPERATING CONDITIONS SYMBOL PARAMETER CONDITIONS LIMITS UNIT SYMBOL PARAMETER CONDITIONS MIN MAX UNIT MIN. MAX. VCC DC supply voltage 3.0 3.6 V VI DC Input voltage range 0 5.5 V VI/O DC input range for I/O 0 5.5 V VAI/O DC input range for analog I/O 0 VCC V VO DC output voltage range 0 VCC V Tamb Operating ambient temperature range in free air See DC and AC characteristics per device 0 +70 °C |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |