| поискавой системы для электроныых деталей |
|
AMS6916 датащи(PDF) 3 Page - Analog Microelectronics GmbH |
|
|
|||||||||||||||||||||||||||||
AMS6916 датащи(HTML) 3 Page - Analog Microelectronics GmbH |
|
3 / 9 page ![]() AMS 6916 Board mount pressure sensor with ratiometric analog output April 2019 – Rev. 1.0, preliminary Page 3/9 www.analog-micro.com SPECIFICATIONS All parameters apply to Top = 25 °C and VS = 5.0 V unless otherwise stated. Parameter Minimum Typical Maximum Units Analog output signal 1) @ specified minimum pressure (see "pressure ranges") 2) 0.5 V @ specified maximum pressure (see "pressure ranges") 2) 4.5 V Full span output (FSO) 3) 4 V without pressure (bidirectional differential types) 2.5 V Accuracy 4) @ T = 25 °C Ultra low pressure sensors (5, 10 mbar) ± 1.0 %FSO Low pressure sensors (20, 50, 100 mbar) ± 0.5 %FSO Standard pressure sensors (> 100 mbar) ± 0.5 %FSO Overall error 5) (TEB) @ T = 0 … 60 °C Ultra low pressure sensors (5, 10 mbar) ± 1.5 %FSO Low pressure sensors (20, 50, 100 mbar) ± 1.0 %FSO Standard pressure sensors (> 100 mbar) ± 1.0 %FSO Long term stability 0.2 6) < 0.5 %FSO/a Resolution A/D converter 14 bits Resolution analog output signal 12 bits Supply voltage range (VS) 4.75 5.00 5.25 V Overall ratiometricity error (@ VS = 4.9 … 5.1 V) 7) ± 0.1 %FSO Current consumption 3 mA Reaction time (10 % … 90 % rise time) 1 2 ms Start up time (Power up to data ready) 8 ms Load resistance at output RL to GND 8) 5 k Ω Capacitive load 15 nF Diagnostic output level 0 … 2.5 and 97.5 … 100 % VS Pressure changes 10 6 Compensated temperature range -25 85 °C Weight 1.5 g Media compatibility See "Specification notes" 9) 10) Table 3: Specifications SPECIFICATION NOTES 1) The analog output signal is ratiometric to the supply voltage. 2) For pressure ranges see Table 1. 3) The Full Span Output (FSO) is the algebraic difference between the output signal at the specified maximum pressure and the output signal at the specified minimum pressure (see "Pressure ranges"). 4) Accuracy is defined as the measurement value’s maximum deviation from the ideal characteristic curve at room temperature (RT) in %FSO including the adjustment error (offset and span), nonlinearity, pressure hysteresis and repeatability. Nonlinearity is the measured deviation from the best fit straight line (BFSL) across the entire pressure range. Pressure hysteresis is the maximum deviation of the output value at any pressure within the specified range when the pressure is cycled to and from the minimum or maximum rated pressure. Repeatability is the maximum deviation of the output value at any pressure within the specified range after 10 pressure cycles. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |