10 / 14 page ![]() ATH25 Data Sheet www.aosong.com Version:V1.0 —— May 2021 10 / 14 Figure 11. Stop transmission state (P) When SCL is high, the SDA line changes from low to high. The stop state is a special bus state controlled by the master, indicating the end of the slave transmission (after Stop, the BUS is generally considered to be in an idle state). 7.3 Send Command After the transmission is started, the first byte of the I2C transmitted subsequently includes the 7-bit I2C device address 0x38 and an SDA direction bit x (read R: ‘1’, write W: ‘0’). After the 8th falling edge of the SCL clock, pull down the SDA pin (ACK bit) to indicate that the sensor data is received normally. After sending the initialization command (‘1110’0001’ represents initialization, ‘1010’1100’ represents temperature and humidity measurement), the MCU must wait until the measurement is completed. The basic commands are summarized in Table 9 and Table 10 shows the status bit description returned by the slave. Command Code Initialization Command 1110‘001 Trigger Measurement 1010’1100 Soft Reset 1011‘1010 Table 9. Basic Command Set Bits Significance Description Bit[7] Busy indication 1-Equipment is busy, in measurement mode 0- Equipment is idle, in hibernation state Bit[6:5] Retain Retain Bit[4] Retain Retain Bit[3] CAL Enable 1 - Calibrated 0 - Uncalibrated Bit[2:0] Retain Retain Table 10. Status bit description 7.4 Sensor Reading Process 1.After power-on, wait no less than 100ms. Before reading the temperature and humidity value, get a byte of status word by sending 0x71. If the status word and 0x18 are not equal to 0x18, initialize the 0x1B, 0x1C, 0x1E registers, details Please refer to our official website routine for the initialization process; if they are equal, proceed to the next step. 2.Wait 10ms to send the 0xAC command (trigger measurement). This command parameter has two bytes, the first byte is 0x33, and the second byte is 0x00. 3.Wait 80ms for the measurement to be completed, if the read status word Bit [7] is 0, it means the measurement is completed, and then six bytes can be read continuously; otherwise, |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |