26 / 64 page ![]() 1998 Jun 17 26 Philips Semiconductors Product specification FLEX ™ Pager Decoder PCD5008 8.5.8 RECEIVER SHUT-DOWN SEQUENCE The PCD5008 allows up to 3 steps associated with shutting down the receiver. When the PCD5008 decides to turn off the receiver, the first shut-down setting, if enabled, is applied to the receiver control lines for the corresponding shut-down time. At the end of the last used shut-down time, the receiver off setting is applied to the receiver control lines. If the first shut-down setting is not enabled, the PCD5008 switches directly from the receiver on to the receiver off setting. Figure 15 shows the receiver shut-down sequence when all shut-down settings are enabled. If the receiver is on or being warmed up when the decoder is turned off (by clearing the ON bit in the control packet), the PCD5008 immediately executes the receiver shut-down sequence. If the PCD5008 is executing the shut-down sequence when turned on (with the ON bit in the control packet set) the PCD5008 completes the shut-down sequence before starting the warm-up sequence. 8.5.8.1 Receiver shut-down setting packets (ID = 1A to 1BH) SE: step enable (Table 21). The receiver setting is enabled when the bit is set. If the bit is cleared then that step in the receiver shut-down sequence is disabled and all following steps are ignored. Value after reset = 0. LBC: low battery check (Table 21). If this bit is set, the PCD5008 checks the status of the LOBAT port just before leaving this receiver shut-down state. Value after reset = 0. CLS: control line setting (Table 21). This is the value to be output on the receiver control lines (S0 to S7) for this receiver shut-down state. Value after reset = 0. ST: step time (Table 21). This sets the duration time for receiver shut-down, until the next receiver state. The setting is in steps of 625 µs. Valid values are 625 µs (ST = 01H) to 39.375 ms (ST = 3FH). Value after reset = 01H. s: setting number, see Tables 20 and 21 for the s names and values and location in the receiver shut-down packet. Table 20 s names and values s SETTING NAME 0 shut-down 1 1 shut-down 2 Table 21 Receiver shut-down stages BYTE BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 30001101 s 2SE0 0 0 LBC 0 0 0 1 CLS7 CLS6 CLS5 CLS4 CLS3 CLS2 CLS1 CLS0 000 ST5 ST4 ST3 ST2 ST1 ST0 Fig.15 Receiver shut-down sequence. handbook, full pagewidth MGK267 receiver control line setting shut down time 1 shut down setting 1 shut down time 2 shut down setting 2 possible LOBAT check off possible LOBAT check possible LOBAT check 1600 sps or 3200 sps sync or data setting |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |