| поискавой системы для электроныых деталей |
|
PCD5003AH датащи(PDF) 13 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCD5003AH датащи(HTML) 13 Page - NXP Semiconductors |
|
13 / 44 page ![]() 1999 Jan 08 13 Philips Semiconductors Product specification Enhanced Pager Decoder for POCSAG PCD5003A Table 9 Call terminator bit identification Note 1. The DF bit in the call terminator is set: a) When any call data code-word in the terminating batch was uncorrectable, while in ‘data receive’ mode. b) When the sync word at the start of the terminating batch did not match the standard POCSAG or a user-programmed sync word, while in ‘data fail’ mode. Table 10 Error type identification (note 1) Note 1. POCSAG code allows a maximum of three bit errors to be detected per code-word. BITS (MSB TO LSB) IDENTIFICATION FT forced call termination (1 = yes) S3 to S1 identifier number of last sync word DF data fail mode indication (1 = data fail mode); note 1 E3 to E1 detected error type; see Table 10; E3 = 0 in a call terminator E3 E2 E1 ERROR TYPE NUMBER OF ERRORS 0 0 0 no errors; correct code-word 0 0 0 1 parity bit in error 1 0 1 0 single bit error 1 + parity 0 1 1 single bit error and parity error 1 1 0 0 not used 1 0 1 4-bit burst error and parity error 3 (e.g. 1101) 1 1 0 2-bit random error 2 1 1 1 uncorrectable code-word 3 or more Call termination can occur on reception of an address code-word (or even a message code-word if in enhanced call termination mode) or when a sync word is not detected while in the ‘data fail’ mode. 7.19 Receiver and oscillator control A paging receiver and an RF oscillator circuit can be controlled independently via enable outputs RXE and ROE respectively. Their operating periods are optimized according to the synchronization mode of the decoder. Each enable signal has its own programmable establishment time (see Table 11). 7.20 External receiver control and monitoring An external controller may enable the receiver control outputs continuously via an I2C-bus command, overruling the normal enable pattern. Data reception continues normally. This mode can be left by means of a reset or an I2C-bus command. External monitoring of the receiver control output RXE is possible via bit D6 in the status register, when enabled via the control register (D2 = 1). Each change of state of output RXE will generate an external interrupt at output INT. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |