1 / 3 page ![]() 060504/14 LEM www .lem.com LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. Page 1/3 Current Transducer LAS 50-TP For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data I PN Primary nominal r.m.s. current 50 A I P Primary current, measuring range 0 .. ± 150 A V OUT Analog output voltage @ I P V REF ± (0.625 ·I P/IPN) V I P = 0 V REF ± 0.025 V R L Output load resistance ≥ 2 k Ω R OUT Output internal resistance < 20 Ω V REF Internal reference voltage 2.5 ± 0.025 V V REF load resistance ≥ 1 M Ω V REF internal resistance 200 Ω V REF external voltage range 2.0 .. 2.8 V C L Max. output capacitive load 1 nF V C Supply voltage (± 5 %) 5 V I C Current consumption @ V C = 5 V typ 18 mA Accuracy - Dynamic performance data X Accuracy 1) @ I PN , TA = 25°C < ± 1 % ε L Linearity error 0 .. I PN 2) < 0.7 % Typ Max TCV OUT Thermal drift of VOUT @ IP = 0 - 40°C.. + 85°C 80 120 ppm/K TCV OUT / VREF Thermal drift of VOUT / VREF @ IP = 0 - 40°C.. + 85°C 50 80 ppm/K TC ε G Thermal drift of the gain - 10°C.. + 85°C 150 300 ppm/K - 40°C.. - 10°C 400 700 ppm/K V OM Residual voltage @ I P = 0, after an overload of 2 x IPN DC ± 5 mV t ra Reaction time @ 10 % of I PN < 200 ns t r Response time @ 90 % of I PN < 500 ns di/dt di/dt accurately followed > 100 A/µs Output noise without external filter < 10 mVpp f Frequency bandwidth (- 1 dB) DC .. 100 kHz General data T A Ambient operating temperature - 40 .. + 85 °C T S Ambient storage temperature - 40 .. + 100 °C m Mass 20 g Standards EN 50178 : 1997 All Data are given with a R L = 10 k Ω Notes : 1) Excluding electrical, magnetic offsets and linearity 2) Including magnetic offset. I PN = 50 A Features • Current transducer using Eta-technology • Unipolar voltage supply • Insulated plastic case recognized according to UL 94-V0 • Compact design for PCB mounting • Extended measuring range. Advantages • Excellent accuracy • Very good linearity • Very low temperature drift • Optimized response time • Wide frequency bandwidth • No insertion losses • High immunity to external interference • Current overload capability. Applications • AC variable speed drives and servo motor drives • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies (UPS) • Switched Mode Power Supplies (SMPS) • Power supplies for welding applications. Application domain • Industrial. Copyright protected. 16069 |
Аналогичный номер детали - LAS50-TP |
|
Аналогичное описание - LAS50-TP |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |