| поискавой системы для электроныых деталей |
|
HMP3 датащи(PDF) 2 Page - Vaisala |
|
|
|||||||||||||||||||||||||||||
HMP3 датащи(HTML) 2 Page - Vaisala |
|
2 / 3 page ![]() Technical data Measurement performance Relative humidity Measurement range 0 … 100 %RH Accuracy at +23 °C (+73.4 °F) 1) ±0.8 %RH (0 … 90 %RH) Factory calibration uncertainty 2) ±0.5 %RH (0 … 40 %RH) ±0.8 %RH (40 … 95 %RH) T63 response time 15 s Sensor options HUMICAPâ R2 HUMICAPâ R2C 3) HUMICAPâ 180VC 3) 4) Temperature Sensor Pt100 RTD Class F0.1 IEC 60751 Measurement range −40 … +120 °C (−40 … +248 °F) Accuracy 1) ±0.1 °C (±0.18 °F) Factory calibration uncertainty 2) ±0.1 °C (±0.18 °F) at +23 °C (+73.4 °F) 1) Defined against calibration reference. Including non-linearity, hysteresis, and repeatability. 2) Defined as ±2 standard deviation limits. Small variations possible; see calibration certificate. 3) Sensor purge feature available with this sensor. 4) H2O2 resistant. With HUMICAPâ 180VC sensor, accuracy is not specified below −20 °C (−4 °F) operating temperature. 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Temperature [°C] 3.5 4.0 90 ... 100 %RH 0 ... 90 %RH HMP3 humidity measurement accuracy as a function of temperature 0 0.1 0.2 0.3 0.4 Temperature [°C] HMP3 temperature measurement accuracy over full range Operating environment Operating temperature of probe head −40 … +120 °C (−40 … +248 °F) Operating temperature of probe body −40 … +80 °C (−40 … +176 °F) Storage temperature −40 … +80 °C (−40 … +176 °F) Operating environment Suitable for outdoor use Measurement environment For air, nitrogen, hydrogen, argon, helium, and oxygen 1) IP rating of probe body IP66 1) Consult Vaisala if other chemicals are present. Consider safety regulations with flammable gases. Inputs and outputs Operating voltage 15 … 30 V DC Current consumption 10 mA typical, 500 mA max. Digital output RS-485, non-isolated Protocols Modbus RTU Output parameters Absolute humidity (g/m3) Relative humidity (%RH) Absolute humidity at NTP (g/m3) Relative humidity (dew/frost) (%RH) Dew point temperature (°C) Temperature (°C) Dew/frost point temperature (°C) Water concentration (ppmv) Dew/frost point temperature at 1 atm (°C) Water concentration (wet basis) (vol‑%) Dew point temperature at 1 atm (°C) Water mass fraction (ppmw) Dew point temperature difference (°C) Water vapor pressure (hPa) Enthalpy (kJ/kg) Water vapor saturation pressure (hPa) Mixing ratio (g/kg) Wet-bulb temperature (°C) Compliance EU directives and regulations EMC Directive (2014/30/EU) RoHS Directive (2011/65/EU) amended by 2015/863 EMC compatibility EN 61326‑1, industrial environment Type approvals DNV GL certificate no. TAA00002YT Compliance marks CE, China RoHS, RCM Mechanical specifications Connector M12 5-pin A-coded male Weight 302 g (10.65 oz) Probe cable length 2 m (6.56 ft) Materials Probe AISI 316L Probe body AISI 316L Cable jacket FEP Accessories Duct installation kit for humidity probe 210697 Solar radiation shield DTR502B DTR502B Cable gland M20×1.5 with split seal HMP247CG Indigo USB adapter 1) USB2 1) Vaisala Insight software for Windows available at www.vaisala.com/insight. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |