| поискавой системы для электроныых деталей |
|
EUD-600SXXXDV датащи(PDF) 8 Page - Inventronics Inc. |
|
|
|||||||||||||||||||||||||||||
EUD-600SXXXDV датащи(HTML) 8 Page - Inventronics Inc. |
|
8 / 20 page ![]() 8 / 20 Specifications are subject to changes without notice. All specifications are typical at 25 C unless otherwise stated 600W Programmable IP67 Driver EUD-600SxxxDV Rev. I www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com Safety &EMC Compliance Safety Category Standard ENEC & TUV & CE EN 61347-1, EN 61347-2-13 CB IEC 61347-1, IEC 61347-2-13 CCC GB 19510.1, GB 19510.14 PSE J 61347-1, J 61347-2-13 KC K 61347-1, K 61347-2-13 BIS IS 15885(Part2/Sec13) EAC ГОСТ Р МЭК 61347-1, ГОСТ IEC 61347-2-13 global-mark AS/NZS 61347.1, AS/NZS 61347.2.13 EMI Standards Notes EN 55015/GB/T 17743/KN 15(1) Conducted emission Test & Radiated emission Test EN 61000-3-2/GB 17625.1 Harmonic current emissions EN 61000-3-3 Voltage fluctuations & flicker EMS Standards Notes EN 61000-4-2 Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge EN 61000-4-3 Radio-Frequency Electromagnetic Field Susceptibility Test-RS EN 61000-4-4 Electrical Fast Transient / Burst-EFT EN 61000-4-5 Surge Immunity Test: AC Power Line: Differential Mode 6 kV, Common Mode 10 kV(2) EN 61000-4-6 Conducted Radio Frequency Disturbances Test-CS EN 61000-4-8 Power Frequency Magnetic Field Test EN 61000-4-11 Voltage Dips EN 61547 Electromagnetic Immunity Requirements Applies To Lighting Equipment Note: (1) This LED driver meets the EMI specifications above, but EMI performance of a luminaire that contains it depends also on the other devices connected to the driver and on the fixture itself. (2) To perform electric strength (hi-pot) testing, the “GDT ground disconnect” (nut and metal lock sheet) on the driver end-cap should be removed temporarily to prevent the internal gas discharge tube from conducting (as allowed by IEC 60598-1 Clause 10.2). After testing is completed, these items must be reinstalled to restore line-to-earth surge protection and secure the end cap. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |