| поискавой системы для электроныых деталей |
|
EMC1001 датащи(PDF) 13 Page - SMSC Corporation |
|
|
|||||||||||||||||||||||||||||
EMC1001 датащи(HTML) 13 Page - SMSC Corporation |
|
13 / 16 page ![]() 1.5°C SMBus Temperature Sensor in Miniature SOT-23 Datasheet SMSC EMC1001 13 Revision 1.6 (01-29-07) DATASHEET Note 4.3 Revision number may change. Please obtain the latest version of this document from the SMSC web site. At device power-up, the default values are stored in all registers. A power-on-reset is initiated when power is first applied to the part and the VDD supply exceeds the POR threshold. Reads of undefined registers will return 00h and writes to undefined registers will be ignored. The EMC1001 uses an interlock mechanism that locks the low byte value when the high byte register is read. This prevents updates to the low byte register between high byte and low byte reads. This interlock mechanism requires that the high byte register always be read prior to reading the low byte register. 4.7 Status Register The status register is a read only register that stores the operational status of the part. When either TLOW or THIGH are set (TA ≤ low limit or TA > high limit) and the ALERT/THERM2 pin is not masked, the ALERT/THERM2 pin will assert. See Section 4.3 on page 11 for more details on the ALERT function. Bit 7 indicates that the ADC is busy converting a value. Bits 6 and 5 indicate that the temperature measurement is above or below the limits respectively. Bit 0 indicates that the measured temperature has exceeded the THERM limit. When bit 0 goes high the ADDR/THERM output will be asserted. Each bit is cleared individually when the status register is read, provided that the error condition for that bit no longer exists. The ALERT/THERM2 output is latched and will not be reset until the host has responded with an alert response address (ARA=0001 100). The ALERT/THERM2 output will not reset if the status register has not been cleared. 4.8 Configuration Register The configuration register controls the functionality of the temperature measurements. Table 4.4 Status Register STATUS REGISTER BIT NAME FUNCTION 7 Busy 1 when ADC is converting 6 THIGH 1 when Temperature High Limit is exceeded 5 TLOW 1 when Temperature Low Limit is exceeded 4Reserved 3Reserved 2Reserved 1Reserved 0 THRM 1 when THERM limit is exceeded |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |