CS82C54 датащи(HTML) 15 Page - Intersil Corporation |
|
15 / 22 page ![]() 15 Counter will be loaded with new count on the next CLK pulse and counting will continue from there. Operation Common To All Modes Programming When a Control Word is written to a Counter, all Control Logic, is immediately reset and OUT goes to a known initial state; no CLK pulses are required for this. Gate The GATE input is always sampled on the rising edge of CLK. In Modes 0, 2, 3 and 4 the GATE input is level sensitive, and logic level is sampled on the rising edge of CLK. In modes 1, 2, 3 and 5 the GATE input is rising-edge sensitive. In these Modes, a rising edge of Gate (trigger) sets an edge-sensitive flip-flop in the Counter. This flip-flop is then sampled on the next rising edge of CLK. The flip-flop is reset immediately after it is sampled. In this way, a trigger will be detected no matter when it occurs - a high logic level does not have to be maintained until the next rising edge of CLK. Note that in Modes 2 and 3, the GATE input is both edge-and level-sensitive. Counter New counts are loaded and Counters are decremented on the falling edge of CLK. The largest possible initial count is 0; this is equivalent to 216 for binary counting and 104 for BCD counting. The counter does not stop when it reaches zero. In Modes 0, 1, 4, and 5 the Counter “wraps around” to the highest count, either FFFF hex for binary counting or 9999 for BCD counting, and continues counting. Modes 2 and 3 are periodic; the Counter reloads itself with the initial count and continues counting from there. N NNN 0 3 0 2 0 1 0 0 FF FF 0 3 WR CLK GATE OUT CW = 1A LSB = 3 NN N N 0 3 0 2 0 3 0 2 0 1 N NNN 0 3 0 2 0 1 0 0 FF FF FF FE WR CLK GATE OUT CW = 1A LSB = 3 WR CLK GATE OUT CW = 1A LSB = 3 N NN 0 0 FF FF LSB = 5 N 0 5 0 4 FIGURE 14. MODE 5 SIGNAL STATUS MODES LOW OR GOING LOW RISING HIGH 0 Disables Counting - Enables Counting 1 - 1) Initiates Counting 2) Resets output after next clock - 2 1) Disables counting 2) Sets output immediately high Initiates Counting Enables Counting 3 1) Disables counting 2) Sets output immediately high Initiates Counting Enables Counting 4 1) Disables Counting - Enables Counting 5 - Initiates Counting - FIGURE 15. GATE PIN OPERATIONS SUMMARY MODE MIN COUNT MAX COUNT 010 110 220 320 410 510 NOTE: 0 is equivalent to 216 for binary counting and 104 for BCD counting. FIGURE 16. MINIMUM AND MAXIMUM INITIAL COUNTS 82C54 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |